| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
CAP1133 bảng dữ liệu(PDF) 33 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
CAP1133 bảng dữ liệu(HTML) 33 Page - Microchip Technology |
|
33 / 63 page ![]() 2015 Microchip Technology Inc. DS00001625B-page 33 CAP1133 Bit 1 - CS2_PTRN - Determines whether CS2 is considered as part of the Multiple Touch Pattern. Bit 0 - CS1_PTRN - Determines whether CS1 is considered as part of the Multiple Touch Pattern. 6.17 Recalibration Configuration Register The Recalibration Configuration register controls the automatic re-calibration routine settings as well as advanced con- trols to program the Sensor Input Threshold register settings. Bit 7 - BUT_LD_TH - Enables setting all Sensor Input Threshold registers by writing to the Sensor Input 1 Threshold register. • ‘0’ - Each Sensor Input X Threshold register is updated individually. • ‘1’ (default) - Writing the Sensor Input 1 Threshold register will automatically overwrite the Sensor Input Threshold registers for all sensor inputs (Sensor Input Threshold 1 through Sensor Input Threshold 3). The individual Sensor Input X Threshold registers (Sensor Input 2 Threshold and Sensor Input 3 Threshold) can be individually updated at any time. Bit 6 - NO_CLR_INTD - Controls whether the accumulation of intermediate data is cleared if the noise status bit is set. • ‘0’ (default) - The accumulation of intermediate data is cleared if the noise status bit is set. • ‘1’ - The accumulation of intermediate data is not cleared if the noise status bit is set. APPLICATION NOTE: Bits 5 and 6 should both be set to the same value. Either both should be set to ‘0’ or both should be set to ‘1’. Bit 5 - NO_CLR_NEG - Controls whether the consecutive negative delta counts counter is cleared if the noise status bit is set. • ‘0’ (default) - The consecutive negative delta counts counter is cleared if the noise status bit is set. • ‘1’ - The consecutive negative delta counts counter is not cleared if the noise status bit is set. Bits 4 - 3 - NEG_DELTA_CNT[1:0] - Determines the number of negative delta counts necessary to trigger a digital re- calibration as shown in Table 6-30. Bits 2 - 0 - CAL_CFG[2:0] - Determines the update time and number of samples of the automatic re-calibration routine. The settings apply to all sensor inputs universally (though individual sensor inputs can be configured to support re-cal- ibration - see Section 6.11). TABLE 6-29: RECALIBRATION CONFIGURATION REGISTERS ADDR R/W Register B7 B6 B5 B4 B3 B2 B1 B0 Default 2Fh R/W Recalibration Configuration BUT_ LD_TH NO_ CLR_ INTD NO_ CLR_ NEG NEG_DELTA_ CNT[1:0] CAL_CFG[2:0] 8Ah TABLE 6-30: NEG_DELTA_CNT BIT DECODE NEG_DELTA_CNT[1:0] Number of Consecutive Negative Delta Count Values 10 00 8 0 1 16 (default) 10 32 1 1 None (disabled) TABLE 6-31: CAL_CFG BIT DECODE CAL_CFG[2:0] Recalibration Samples (see Note 6-1) Update Time (see Note 6-2) 21 0 0 0 0 16 16 00 1 32 32 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |