39 / 93 page ![]() Ultrasonic-Flow-Converter TDC-GP22 3-16 acam messelectronic gmbh - Friedrich-List-Str.4 - 76297 Stutensee - Germany - www.acam.de The ratio of the discharge times equal the ratio of resistance: RT = Rref * T/ref 3.2.2 Status Register Table 3-3: Status registers Bits Name Description Values 2 – 0 ALU_OP_PTR ALU operation pointer. Pointer to the result register. See description below 5 – 3 # of hits Ch 1 Number of hits registered on channel 1 8 – 6 # of hits Ch 2 Number of hits registered on channel 2 9 Timeout TDC Indicates an overflow of the TDC unit 1 = overflow 10 Timeout Precounter Indicates an overflow of the 14 bit precounter in MR 2 1 = overflow 11 Error open Indicates an open sensor at temperature measurement 1 = open 12 Error short Indicates a shorted sensor at temperature measurement 1 = short 13 EEPROM_Error Single error in EEPROM which has been corrected 1 = error 14 EEPROM_DED Double error detection. A multiple error has been detected which can not be corrected. 1 = multiple error 15 EEPROM_eq_CREG Indicates whether the content of the configuration registers equals the EEPROM 1 = equal ALU Operation Pointer Description: The ALU operation pointer is stored in bits 0-2 of the status register (range of 0x00 to 0x03) and provides an index to one of the 4 results registers (RES_0 to RES_3) as follows: When the EN_AUTOCALC_MB2 parameter is set to 0, and therefore autocalculation is OFF, the ALU operation pointer is set to the next free result register that will be used by the ALU for its next TDC cycle. This occurs once a TDC measurement is performed. Therefore after a TDC measurement ALU_OP_PTR minus 1 will point to the ALU result. When EN_AUTOCALC_MB2 is 1 (autocalculation ON) and once a TDC measurement is performed the ALU operation pointer is set to the result register that contains the sum of the hit calculations stored in RES_0 to RES_2. This calculation does not Member of the ams Group |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |