| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAX6740XKL bảng dữ liệu(PDF) 12 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX6740XKL bảng dữ liệu(HTML) 12 Page - Maxim Integrated Products |
|
12 / 16 page ![]() Low-Power Dual-/Triple-Voltage SC70 µP Supervisory Circuits 12 ______________________________________________________________________________________ Adding Hysteresis to the Power-Fail Comparator The power-fail comparator has a typical input hystere- sis of 2.5mV. This is sufficient for most applications in which a power-supply line is being monitored through an external voltage-divider. If additional noise margin is desired, connect a resistor between PFO and PFI, as shown in Figure 6. Select the values of R1, R2, and R3 such that PFI sees VTH-PFI (488mV) when VEXT falls to its power-fail trip point (VFAIL) and when VEXT rises to its power-good trip point (VGOOD). The hysteresis win- dow extends between the specified VFAIL and VGOOD thresholds. R3 adds the additional hysteresis by sink- ing current from the R1/R2 divider network when the PFO output is logic low and sourcing current into the network when PFO is logic high. R3 is typically an order of magnitude greater than R1 or R2. The current through R2 should be at least 1µA to ensure that the 10nA (max) PFI input current does not significant- ly shift the trip points. Therefore, for most applications: R2 < VTH-PFI / 1mA < 0.488V / 1mA < 488k Ω PFO is an open-drain output requiring an external pullup resistor, R4. Select R4 to be less than 1% of R3. VGOOD = DESIRED VEXT GOOD VOLTAGE THRESHOLD VFAIL = DESIRED VEXT FAIL VOLTAGE THRESHOLD VPU = VPULLUP (FOR OPEN-DRAIN PFO) R2 = 488k Ω (FOR >1µA R2 CURRENT) R3 = (R1 x VPU) / (VGOOD - VFAIL) R4 ≤ 0.01 x R3 Power Sequencing Applications Many dual-voltage processors/ASICs require specific power-up/power-down sequences for the I/O and core supplies. RR VV VV V V V GOOD TH PFI TH PFI GOOD FAIL PU TH PFI 12 = () () − − - - - - ( MAX6742 MAX6745 PFI GND VEXT_TH A) VIN IS POSITIVE R1 R2 PFO VEXT_TH = VTH-PFI R1 + R2 R2 () MAX6742 MAX6745 PFI GND VEXT_TH VCC B) VIN IS NEGATIVE R1 R2 PFO VEXT_TH = R2 1 R1 1 R2 VCC R1 + ( () ) - (VTH-PFI) VPFI = 488mV Figure 4. Using Power-Fail Input to Monitor an Additional Power Supply MAX6737 MAX6739 MAX6743 MAX6744 MAX6745 GND GND VCC1VCC2 VCC2 VCC1 RESET RESET TO OTHER SYSTEM COMPONENTS RESET µP 4.7k Ω Figure 5. Interfacing to µPs with Bidirectional Reset I/O MAX6742 MAX6745 VEXT R1 R4 R3 R2 PFI GND PFO VGOOD = DESIRED VEXT GOOD VOLTAGE THRESHOLD VFAIL = DESIRED VEXT FAIL VOLTAGE THRESHOLD VOH = VCC1 (FOR PUSH-PULL PFO) R2 = 200k Ω (FOR > 2.5µA R2 CURRENT) R1 = R2 ((VGOOD - VTH-PFI) - (VTH-PFI)(VGOOD - VFAIL) / VPU) / VTH-PFI R3 = (R1 x VOH) / (VGOOD - VFAIL) VGOOD VFAIL VIN PFO VPULLUP Figure 6. Adding Hysteresis to Power Fail for Push-Pull PFO |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |