14 / 47 page ![]() Reading angular rate data AN4506 14/47 DocID026442 Rev 2 Figure 3. Data synchronization: level sensitive Figure 4. Level-sensitive trigger stamping 3.5.2 Pulse sensitive trigger (LVLen = 1; EXTRen = 0; IMPen = 1) The pulse-sensitive trigger is similar to the level-sensitive trigger, and has to be used if the duration of the DEN pulse is shorter than the selected gyroscope ODR. Once enabled, the LSB bit of the gyroscope X, Y, Z output data generated after the pulse is set to 1; if no pulse occurs, the LSB bit of the next generated gyroscope X, Y, Z output data is set to 0. When ODR selected is 800 Hz, the maximum DEN sample frequency is fDEN = 1/TDEN = 400 Hz. Figure 5. Data synchronization: pulse sensitive |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|