công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

AN4144 bảng dữ liệu(PDF) 14 Page - STMicroelectronics

tên linh kiện AN4144
Giải thích chi tiết về linh kiện  Voltage mode control operation and parameter optimization
PDF  28 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  STMICROELECTRONICS [STMicroelectronics]
Trang chủ  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

AN4144 bảng dữ liệu(HTML) 14 Page - STMicroelectronics

Back Button AN4144 Datasheet HTML 10Page - STMicroelectronics AN4144 Datasheet HTML 11Page - STMicroelectronics AN4144 Datasheet HTML 12Page - STMicroelectronics AN4144 Datasheet HTML 13Page - STMicroelectronics AN4144 Datasheet HTML 14Page - STMicroelectronics AN4144 Datasheet HTML 15Page - STMicroelectronics AN4144 Datasheet HTML 16Page - STMicroelectronics AN4144 Datasheet HTML 17Page - STMicroelectronics AN4144 Datasheet HTML 18Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 28 page
background image
Tuning of the BEMF compensation parameters
AN4144
14/28
DocID023491 Rev 3
Figure 6. Phase inductance measurement
The ke is the coefficient that relates the motor speed to the BEMF amplitude. This value is
not usually present on stepper motor datasheets, but it can be easily measured by means of
an oscilloscope:
Connect one of the motor phases to an oscilloscope channel
Set the oscilloscope to the trigger value on the rising or falling edge of the channel and
set the threshold value close to zero (few mV above or below zero)
Turn the motor shaft. This can be done by hand or by means of another motor. The
most important thing is to obtain a rotation speed as constant as possible
Set oscilloscope time and voltage scales in order to display a sine wave during the
motor rotation.
If the rotor is turned by hand, the operations should be repeated until a good sine wave is
obtained. A good sine wave keeps its amplitude constant for at least 2 or 3 cycles (Figure 7
and Figure 8). This operation might require several attempts.
Measure the peak voltage to frequency ratio of the sine wave. The resulting value is the
motor electric constant expressed in V/Hz.
Phase A
Phase B
V
I
ph
I
ph
V
ph
V
ph
(A)
(B)
63%
T = L
ph/Rph
AM12862v1
Figure 7. Bad ke measurement waveform
Figure 8. Good ke measurement waveform



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com