| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SPC56EC74L7 bảng dữ liệu(PDF) 70 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPC56EC74L7 bảng dữ liệu(HTML) 70 Page - STMicroelectronics |
|
70 / 118 page ![]() Electrical Characteristics SPC564Bxx - SPC56ECxx 70/118 Doc ID 17478 Rev 4 Table 27 shows the data flash memory program and erase characteristics. ECC circuitry provides correction of single bit faults and is used to improve further automotive reliability results. Some units will experience single bit corrections throughout the life of the product with no impact to product reliability. Table 27. Data flash memory—Program and erase specifications Symbol C Parameter Value Unit Min Typ(1) Initial max(2) Max(3) Twprogram CC C Word (32 bits) program time(4) — 30 70 500 µs T16Kpperase 16 KB block pre-program and erase time — 700 800 5000 ms Teslat D Erase Suspend Latency — — 30 30 µs tESRT C Erase Suspend Request Rate 10 — — — ms tPABT D Program Abort Latency — — 12 12 µs tEAPT D Erase Abort Latency — — 30 30 µs 1. Typical program and erase times assume nominal supply values and operation at 25 °C. All times are subject to change pending device characterization. 2. Initial factory condition: < 100 program/erase cycles, 25 °C, typical supply voltage. 3. The maximum program and erase times occur after the specified number of program/erase cycles. These maximum values are characterized but not guaranteed. 4. Actual hardware programming times. This does not include software overhead. Table 28. Flash memory module life Symbol C Parameter Conditions Value Unit Min Typ P/E CC C Number of program/erase cycles per block for 16 Kbyte blocks over the operating temperature range (TJ) — 100000 100000 cycles Number of program/erase cycles per block for 32 Kbyte blocks over the operating temperature range (TJ) — 10000 100000 cycles Number of program/erase cycles per block for 128 Kbyte blocks over the operating temperature range (TJ) — 1000 100000 cycles Retention CC C Minimum data retention at 85 °C average ambient temperature(1) Blocks with 0–1000 P/E cycles 20 — years Blocks with 10000 P/E cycles 10 — years Blocks with 100000 P/E cycles 5— years 1. Ambient temperature averaged over duration of application, not to exceed recommended product operating temperature range. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |