công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

SA56004GD bảng dữ liệu(PDF) 18 Page - NXP Semiconductors

tên linh kiện SA56004GD
Giải thích chi tiết về linh kiện  짹1 째C accurate, SMBus-compatible, 8-pin, remote/local digital temperature sensor with overtemperature alarms
PDF  36 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  NXP [NXP Semiconductors]
Trang chủ  http://www.nxp.com
Logo NXP - NXP Semiconductors

SA56004GD bảng dữ liệu(HTML) 18 Page - NXP Semiconductors

Back Button SA56004GD Datasheet HTML 14Page - NXP Semiconductors SA56004GD Datasheet HTML 15Page - NXP Semiconductors SA56004GD Datasheet HTML 16Page - NXP Semiconductors SA56004GD Datasheet HTML 17Page - NXP Semiconductors SA56004GD Datasheet HTML 18Page - NXP Semiconductors SA56004GD Datasheet HTML 19Page - NXP Semiconductors SA56004GD Datasheet HTML 20Page - NXP Semiconductors SA56004GD Datasheet HTML 21Page - NXP Semiconductors SA56004GD Datasheet HTML 22Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 36 page
background image
SA56004X_5
© NXP B.V. 2008. All rights reserved.
Product data sheet
Rev. 05 — 22 May 2008
18 of 36
NXP Semiconductors
SA56004X
Digital temperature sensor with overtemperature alarms
LOW. Furthermore, if the Remote HIGH Setpoint High Byte (RHSHB) register is set to a
value less than +127
°C and the Alert Mask is disabled, then the ALERT output will be
pulled LOW. Note that the OPEN bit itself will not trigger an ALERT.
When the D+ pin is shorted to ground or to D
−, the Remote Temperature High Byte
(RTHB) register is loaded with
−128 °C (1000 0000) and the OPEN (bit 2 in the Status
register) will not be set. Since operating the SA56004X is beyond its normal limits, this
temperature reading represents this shorted fault condition. If the value in the Remote
Low Setpoint High Byte (RLSHB) register is more than
−128 °C and the Alert Mask is
disabled, the ALERT output will be pulled LOW.
7.10 SMBus interface
The device can communicate over a standard two-wire serial interface System
Management Bus (SMBus) or compatible I2C-bus using SCLK and SDATA. The device
employs four standard SMBus protocols: Write Byte, Read Byte, Receive Byte, and
Send Byte. Data formats of four protocols are shown in Figure 9. The following key points
of protocol are important:
• The SMBus master initiates data transfer by establishing a START condition (S) and
terminates data transfer by generating a STOP condition (P).
• Data is sent over the serial bus in sequences of 9 clock pulses according to each 8-bit
data byte followed by 1-bit status of device acknowledgement (A).
• The 7-bit slave address is equivalent to factory-programmed address of the device.
• The command byte is equivalent to the address of the selected device register.
• The Receive Byte format is used for quicker transfer data from a device reading
register that was previously selected.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com