| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
HAL855 bảng dữ liệu(PDF) 22 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
HAL855 bảng dữ liệu(HTML) 22 Page - Micronas |
|
22 / 42 page ![]() HAL855 DATA SHEET 22 Nov. 26, 2008; DSH000149_003EN Micronas 3.6. Characteristics at TJ = −40 °C to +170 °C, VDD = 4.5 V to 14 V, after programming and locking of the device, at Recommended Operation Conditions if not otherwise specified in the column “Conditions”. Typical Characteristics for TJ = 25 °C and VDD = 5 V. All voltages listed are referenced to ground (GND). Symbol Parameter Pin No. Min. Typ. Max. Unit Conditions IDD Supply Current over Temperature Range 1 − − 7 7 8 10 mA mA TJ > 125°C TJ < 125°C IOH Output Leakage Current over Temperature Range 3 −− 10 µA VDDZ Overvoltage Protection at Supply 1 − 22 − V VOZ Overvoltage Protection at Output 3 − 22 − V Resolution 2,3 −− 12 bit 1) INL Integral Non-Linearity over Temperature Range 2,3 −0.5 0 0.5 % 2) fPWM PWM Output Frequency over Temperature Range 3 920 460 230 115 57 28 13 6.5 1000 500 250 125 62.5 31 15 7.5 1080 540 270 135 68 34 17 8.5 Hz Hz Hz Hz Hz Hz Hz Hz PWM period: 1 ms; 9 bit res. PWM period: 2 ms; 10 bit res. PWM period: 4 ms; 11 bit res. PWM period: 8 ms; 12 bit res. PWM period: 16 ms; 12 bit res. PWM period: 32 ms; 12 bit res. PWM period: 64 ms; 12 bit res. PWM period: 128 ms;12 bit res. tp0 Biphase-M Output Bittime over Temperature Range 30.03 2 0.04 3.2 0.05 4 ms ms Biphase-M bit time: 40 μs Biphase-M bit time: 3.2 ms tp1 Biphase-M Output Timing for Logical 1 3 5065 80% fADC Internal ADC Frequency over Temperature Range − 110 128 150 kHz VDD = 4.5 V to 14 V tr(O) Response Time of Internal Signal3) 3 − − − 5 4 2 1 10 8 4 2 ms ms ms ms 3 dB filter frequency = 80 Hz 3 dB filter frequency = 160 Hz 3 dB filter frequency = 500 Hz 3 dB filter frequency = 2 kHz td(O) Delay Time of Internal Signal 3 − 0.1 0.5 ms tPOD Power-Up Time (time to reach stabilized internal signal)3) − − − 6 5 3 2 11 9 5 3 ms ms ms ms 3 dB filter frequency = 80 Hz 3 dB filter frequency = 160 Hz 3 dB filter frequency = 500 Hz 3 dB filter frequency = 2 kHz 1) if the Hall IC is programmed suitably 2) if more than 50% of the selected magnetic field range are used and the Hall IC is programmed suitably 3) The output signal is updated at the begin of each PWM period or Biphase-M period. The update time depends on the output format settings. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |