| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
STM32F103xC bảng dữ liệu(PDF) 88 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STM32F103xC bảng dữ liệu(HTML) 88 Page - STMicroelectronics |
|
88 / 123 page ![]() Electrical characteristics STM32F103xC, STM32F103xD, STM32F103xE 88/123 Doc ID 14611 Rev 7 5.3.16 Communications interfaces I 2C interface characteristics Unless otherwise specified, the parameters given in Table 50 are derived from tests performed under ambient temperature, fPCLK1 frequency and VDD supply voltage conditions summarized in Table 10. The STM32F103xC, STM32F103xD and STM32F103xE performance line I 2C interface meets the requirements of the standard I 2C communication protocol with the following restrictions: the I/O pins SDA and SCL are mapped to are not “true” open-drain. When configured as open-drain, the PMOS connected between the I/O pin and VDD is disabled, but is still present. The I 2C characteristics are described in Table 50. Refer also to Section 5.3.13: I/O port characteristics for more details on the input/output alternate function characteristics (SDA and SCL). Table 50. I2C characteristics Symbol Parameter Standard mode I2C(1) 1. Guaranteed by design, not tested in production. Fast mode I2C(1)(2) 2. fPCLK1 must be higher than 2 MHz to achieve the maximum standard mode I 2C frequency. It must be higher than 4 MHz to achieve the maximum fast mode I2C frequency. Unit Min Max Min Max tw(SCLL) SCL clock low time 4.7 1.3 µs tw(SCLH) SCL clock high time 4.0 0.6 tsu(SDA) SDA setup time 250 100 ns th(SDA) SDA data hold time 0(3) 3. The maximum hold time of the Start condition has only to be met if the interface does not stretch the low period of SCL signal. 0(4) 4. The device must internally provide a hold time of at least 300ns for the SDA signal in order to bridge the undefined region of the falling edge of SCL. 900(3) tr(SDA) tr(SCL) SDA and SCL rise time 1000 20 + 0.1Cb 300 tf(SDA) tf(SCL) SDA and SCL fall time 300 300 th(STA) Start condition hold time 4.0 0.6 µs tsu(STA) Repeated Start condition setup time 4.7 0.6 tsu(STO) Stop condition setup time 4.0 0.6 s tw(STO:STA) Stop to Start condition time (bus free) 4.7 1.3 s Cb Capacitive load for each bus line 400 400 pF |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |