công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

AS4SD4M16DG-10/IT bảng dữ liệu(PDF) 12 Page - Austin Semiconductor

tên linh kiện AS4SD4M16DG-10/IT
Giải thích chi tiết về linh kiện  4 Meg x 16 SDRAM Synchronous DRAM Memory
PDF  50 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  AUSTIN [Austin Semiconductor]
Trang chủ  http://www.austinsemiconductor.com
Logo AUSTIN - Austin Semiconductor

AS4SD4M16DG-10/IT bảng dữ liệu(HTML) 12 Page - Austin Semiconductor

Back Button AS4SD4M16DG-10/IT Datasheet HTML 8Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 9Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 10Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 11Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 12Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 13Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 14Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 15Page - Austin Semiconductor AS4SD4M16DG-10/IT Datasheet HTML 16Page - Austin Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 50 page
background image
SDRAM
SDRAM
SDRAM
SDRAM
SDRAM
AS4SD4M16
AS4SD4M16
Rev. 2.1 6/05
Austin Semiconductor, Inc. reserves the right to change products or specifications without notice.
12
Austin Semiconductor, Inc.
OPERATION
BANK/ROW ACTIVATION
Before any READ or WRITE commands can be issued
to a bank within the SDRAM, a row in that bank must be
“opened.” This is accomplished via the ACTIVE command,
which selects both the bank and the row to be activated.
After opening a row (issuing an ACTIVE command), a
READ or WRITE command may be issued to that row, subject
to the
t
RCD
specification.
t
RCD
(MIN) should be divided by the
clock period and rounded up to the next whole number to deter-
mine the earliest clock edge after the ACTIVE command on
which a READ or WRITE command can be entered. For
example, a
t
RCD
specification of 30ns with a 90 MHz clock
(11.11ns period) results in 2.7 clocks, rounded to 3. This is
reflected in Figure 4, which covers any case where 2 <
t
RCD
(MIN)/
t
CK ≤
3. (The same procedure is used to convert other
specification limits from time units to clock cycles).
A subsequent ACTIVE command to a different row in
the same bank can only be issued after the previous active row
has been “closed” (precharged). The minimum time interval
between successive ACTIVE commands to the same bank is
defined by
t
RC
.
A subsequent ACTIVE command to another bank can
be issued while the first bank is being accessed, which results
in a reduction of total row-access overhead. The minimum time
interval between successive ACTIVE commands to different
banks is defined by
t
RRD
.
Figure 4
EXAMPLE: MEETING t
RCD
(MIN) WHEN 2<t
RCD
(MIN)/t
CK
<3
1234
1234
1234
DON’T CARE
CLK
COMMAND
t
RCD
1234
1234
1234
1234
1234
12
12
12
12
12
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
ACTIVE
NOP
T0
T1
T2
T3
12345
12345
12345
12345
12345
NOP
T4
12345
12345
12345
12345
12345
READ or
WRITE
Figure 3
ACTIVATING A SPECIFIC ROW IN A
SPECIFIC BANK
CLK
CKE
HIGH
CS\
123456789
123456789
123456789
123456789012
123456789012
123456789012
12
12
1
1
12345
12345
12345
123456789012
123456789012
123456789012
12
12
12
12
RAS\
123456789
123456789
123456789
123456789012
123456789012
123456789012
1
1
1
1
1
1
12345
12345
12345
123456789012
123456789012
123456789012
12
12
12
12
12
12
123456789
123456789
123456789
123456789
123456789
123456789
1
1
1
1
1
1
123456
123456
123456
123456789012345
123456789012345
123456789012345
1
1
1
1
1
1
CAS\
123456789
123456789
123456789
123456789
123456789
123456789
1
1
1
1
123456
123456
123456
123456789012345
123456789012345
123456789012345
1
1
1
1
WE\
1234
1234
1234
1234567890123456
1234567890123456
1234567890123456
12
12
12
12
123
123
123
1234567890123
1234567890123
1234567890123
12
12
12
12
1234
1234
1234
1234567890123456
1234567890123456
1234567890123456
1
1
1
12
12
12
123
123
123
1234567890123
1234567890123
1234567890123
12
12
12
1
1
1
A0-A11
BA0, 1
ROW ADDRESS
BANK ADDRESS



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com