73 / 325 page ![]() Rev.1.00 2004.03.23 page 73 of 320 M306H3MC-XXXFP/FCFP 2.7.10 Address Match Interrupt An address match interrupt request is generated immediately before executing the instruction at the ad- dress indicated by the RMADi register (i=0 to 3). Set the start address of any instruction in the RMADi register. Use the AIER register’s AIER0 and AIER1 bits and the AIER2 register’s AIER20 and AIER21 bits to enable or disable the interrupt. Note that the address match interrupt is unaffected by the I flag and IPL. For address match interrupts, the value of the PC that is saved to the stack area varies depending on the instruction being executed (refer to “Saving Registers”). (The value of the PC that is saved to the stack area is not the correct return address.) Therefore, follow one of the methods described below to return from the address match interrupt. • Rewrite the content of the stack and then use the REIT instruction to return. • Restore the stack to its previous state before the interrupt request was accepted by using the POP or similar other instruction and then use a jump instruction to return. Table 2.7.6 shows the value of the PC that is saved to the stack area when an address match interrupt request is accepted. Note that when using the external bus in 8 bits width, no address match interrupts can be used for external areas. Figure 2.7.13 shows the AIER, AIER2, and RMAD0 to RMAD3 registers. Table 2.7.6. Instruction Just Before Execution and Address Stored in Stack When There Occurs Interrupts Table 2.7.7. Relationship Between Address Match Interrupt Sources and Associated Registers Address match interrupt sources Address match interrupt enable bit Address match interrupt register Address match interrupt 0 AIER0 RMAD0 Address match interrupt 1 AIER1 RMAD1 Address match interrupt 2 AIER20 RMAD2 Address match interrupt 3 AIER21 RMAD3 • 16-bit op-code instruction • Instruction shown below among 8-bit operation code instructions ADD.B:S #IMM8,dest SUB.B:S #IMM8,dest AND.B:S #IMM8,dest OR.B:S #IMM8,dest MOV.B:S #IMM8,dest STZ.B:S #IMM8,dest STNZ.B:S #IMM8,dest STZX.B:S #IMM81,#IMM82,dest CMP.B:S #IMM8,dest PUSHM src POPM dest JMPS #IMM8 JSRS #IMM8 MOV.B:S #IMM,dest (However, dest=A0 or A1) Instructions other than the above Instruction at the address indicated by the RMADi register Value of the PC that is saved to the stack area The address indicated by the RMADi register +2 The address indicated by the RMADi register +1 Value of the PC that is saved to the stack area : Refer to “Saving Registers”. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |