59 / 224 page ![]() 59/224 ST92163 - INTERRUPTS 3.11 INTERRUPT REGISTERS CENTRAL INTERRUPT CONTROL REGISTER (CICR) R230 - Read/Write Register Page: System Reset value: 1000 0111 (87h) Bit 7 = GCEN: Global Counter Enable. This bit enables the 16-bit Multifunction Timer pe- ripheral. 0: MFT disabled 1: MFT enabled Bit 6 = TLIP: Top Level Interrupt Pending. This bit is set by hardware when Top Level Inter- rupt (TLI) trigger event occurs. It is cleared by hardware when a TLI is acknowledged. It can also be set by software to implement a software TLI. 0: No TLI pending 1: TLI pending Bit 5 = TLI: Top Level Interrupt. This bit is set and cleared by software. 0: Generate a Top Level Interrupt only if TLNM=1 1: Generate a Top Level Interrupt request when the IEN and TLIP bits=1. Bit 4 = IEN: Interrupt Enable. This bit is cleared by the interrupt machine cycle (except for a TLI). It is set by the iret instruction (except for a return from TLI). It is set by the EI instruction. It is cleared by the DI instruction. 0: Maskable interrupts disabled 1: Maskable Interrupts enabled Note: The IEN bit can also be changed by soft- ware using any instruction that operates on regis- ter CICR, however in this case, take care to avoid spurious interrupts, since IEN cannot be cleared in the middle of an interrupt arbitration. Only modify the IEN bit when interrupts are disabled or when no peripheral can generate interrupts. For exam- ple, if the state of IEN is not known in advance, and its value must be restored from a previous push of CICR on the stack, use the sequence DI; POP CICR to make sure that no interrupts are be- ing arbitrated when CICR is modified. Bit 3 = IAM: Interrupt Arbitration Mode. This bit is set and cleared by software. 0: Concurrent Mode 1: Nested Mode Bit 2:0 = CPL[2:0]: Current Priority Level. These bits define the Current Priority Level. CPL=0 is the highest priority. CPL=7 is the lowest priority. These bits may be modified directly by the interrupt hardware when Nested Interrupt Mode is used. EXTERNAL INTERRUPT TRIGGER REGISTER (EITR) R242 - Read/Write Register Page: 0 Reset value: 0000 0000 (00h) Bit 7 = TED1: INTD1 Trigger Event Must always stay cleared Bit 6 = TED0: INTD0 Trigger Event Bit 5 = TEC1: INTC1 Trigger Event Bit 4 = TEC0: INTC0 Trigger Event Bit 3 = TEB1: INTB1 Trigger Event Bit 2 = TEB0: INTB0 Trigger Event Bit 1 = TEA1: INTA1 Trigger Event Bit 0 = TEA0: INTA0 Trigger Event These bits are set and cleared by software. 0: Select falling edge as interrupt trigger event 1: Select rising edge as interrupt trigger event 70 GCEN TLIP TLI IEN IAM CPL2 CPL1 CPL0 70 TED1 TED0 TEC1 TEC0 TEB1 TEB0 TEA1 TEA0 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |