| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PTPLD1202DYYR bảng dữ liệu(PDF) 83 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PTPLD1202DYYR bảng dữ liệu(HTML) 83 Page - Texas Instruments |
|
83 / 192 page ![]() Table 7-33. User Register Lock Access Type Enumeration (continued) Register Lock bits Voltage Reference select for Analog Comparator (0x070 - 0x07F) R/W R R R/W — R/W — Virtual Input (0x0E0) R/W R/W R/W R/W R/W R/W R/W Virtual Output (0x0E1) R R R R R R R CRC Status (0x0FE) R R R R R R R Configuration Registers (0x200 - 0x3FF) R/W R/W R/W R/W W R — Any write commands that come to the device via the serial communications interface that are not blocked, based on the protection bits, changes the contents of the configuration register that mirror the OTP bits. These write commands do not change the OTP bits themselves, and a POR event restores the register bits to original programmed contents of the OTP. 7.4.3.2 OTP Cyclic Redundancy Check (CRC) Cyclic Redundancy Checks (CRCs) is a common method of performing error checking on areas of OTP and verifying data integrity of this memory. OTP is used to configure the macro-cells and connection mux routing of the TPLD1202. The OTP is one-time programmable and holds the device configuration data. OTP memory is loaded during device power up and transferred to TPLD1202 connection mux. To verify the bit integrity of the OTP memory before the stored configuration is loaded from OTP to device registers, as a safety measure, TPLD1202 implements a cyclic redundancy check (CRC) feature for the OTP to make sure that the data stored in the OTP is uncorrupted. At start-up, the OTP is read internally and checks for a valid CRC. If the CRC is not valid, this process is performed for a total of 7 more times. If still not valid after the 8th attempt, the device proceeds with loading the contents from OTP but sets the following status bits: CRC_ERR_CNT bits: The CRC_ERR_CNT bits in register 0x0FEh [7:5] indicate the number of failed CRC attempts before loading the OTP contents into the configuration of the device. CRC_ERR_FLAG bit: The CRC_ERR_FLAG bit in register 0x0FEh [0] indicates there are more than 8 CRC calculation failures in the loading of the OTP contents into the configuration of the device. 7.4.4 Programming The TPLD1202 is programmed through a I2C or SPI. In the programmed case for the TPLD1202 device, the configuration choices made by the user are stored as bit settings in the OTP, and this information is transferred at startup time to connection mux registers that enable the configuration of the macro-cells and for setting the connections in the connection mux to route signals in the manner most appropriate for the user’s application. www.ti.com TPLD1202 SCPS289B – SEPTEMBER 2024 – REVISED AUGUST 2026 Copyright © 2026 Texas Instruments Incorporated Submit Document Feedback 83 Product Folder Links: TPLD1202 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |