| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PTPLD1202DYYR bảng dữ liệu(PDF) 57 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PTPLD1202DYYR bảng dữ liệu(HTML) 57 Page - Texas Instruments |
|
57 / 192 page ![]() 7.3.7.1 State Machine Inputs The state machine macro-cell has 18 inputs from the connection mux: 16 state transition inputs, 1 clock input, and 1 reset input. Each of the 16 state transition inputs are active-high inputs, meaning a high-level input triggers a state transition given the timing considerations are met. Further, these 24 inputs are grouped such that each set of 2 inputs drives a transition into a particular state. For example, there are 2 inputs that drives a transition from any state into State 2. Thus, this limits the maximum number of transitions into a particular state to 2. When operating the state machine in synchronous mode and a state transition condition is met, the state transition occurs on the next rising edge of the clock input. In asynchronous mode, when a state transition condition is met, the state transition occurs asynchronously and the clock input is unavailable/ignored. There is also an active-low, asynchronous reset input which, when asserted, puts the state machine into the user-selected initial state and, when released, returns the state machine into normal operation from the initial state. 7.3.7.2 State Machine Outputs The state machine macro-cell has 8 outputs into the connection mux. With a 1-byte RAM per state, users are able to set the behavior of the 8 outputs for each defined state, which could be seen as 8 parallel outputs that can be configured depending on the current state. Each of the 8 outputs are connection mux inputs that could be elsewhere in the design, such as an input into a LUT, D flip-flop, counter, or out to a GPO pin. The state machine outputs can be updated in-system using the User Registers. For glitch-free operation, it is recommended to put the state machine in a reset while the state machine output bits are being modified. 7.3.7.3 Configuring the State Machine The following can be configured for an operating state machine: states, initial state, state transitions, mode, clock polarity. • States: Up to 8 states can be created and renamed, if desired. • Initial state: One of the states creates can be selected as the initial state in which the state machine macro-cell resets to following an asynchronous reset. • State transitions: Users can set the transition from one state into another to enable a state transition condition input, with a maximum of 2 transitions into a particular state. The state transition conditions are inputs from the connection mux and can be configured to come from any GPI or other macro-cell outputs. • Mode: The state machine can be selected to operate in synchronous mode, in which state transition conditions are synchronously latched in with respect to the clock input, or asynchronous mode. • Clock sync: In synchronous mode, this setting determines whether the state machine is rising edge triggered (sync disabled), that is state transition inputs and state transitions are latched in on the rising edge of the clock, or falling edge triggered (sync enabled). The serial communication interface, if enabled, can be used to read the current state of an active state machine and reconfigure the state outputs. Any changes made to the state machine configuration through the serial communication interface only reflects after the next state transition or a reset event. Thus, to establish the desired behavior, best practice is to keep the state machine in reset while reconfiguring the macro-cell. 7.3.7.4 State Machine Timing Considerations When the state machine macro-cell is in operation, especially when operating asynchronously, the state transition inputs timing requirement, delays in the I/O, other macro-cells used in the state transition input path, and the connection mux need to be taken into consideration to verify inputs are properly processed and state transitions are deterministic. In synchronous mode, state transition trigger input needs to be asserted for at least 3 clock cycles. In asynchronous mode, the state transition trigger input needs to be asserted for at least the state transition pulse width, tst_pw. If a state transition condition is met, the transition occurs after the state transition delay, tst_dly. www.ti.com TPLD1202 SCPS289B – SEPTEMBER 2024 – REVISED AUGUST 2026 Copyright © 2026 Texas Instruments Incorporated Submit Document Feedback 57 Product Folder Links: TPLD1202 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |