24 / 39 page ![]() DIO1413/1414 Version 1.2, Sep 2024 www.dioo.com © 2024 DIOO MICROCIRCUITS CO., LTD. 20 FDh R Product ID (DIO1414) Stores a fixed value that identifies the device B7h FEh R Manufacturer ID Stores a fixed value that identifies DIOO DAh FFh R Revision Stores a fixed value that represents the revision number 05h Note: R = Read, W = Write, R-C = Read then Clear. 12.1. Temperature data registers The measured temperatures of all channels are stored as a 12-bit value with the high byte representing the integer data and the low byte representing the fractional data as shown in the following register table. It should be noted that when any channel’s temperature high byte register is read, the corresponding low byte is copied into an internal “shadow” register. The user is free to read the low byte at any time. No matter the low byte is read or not, reading from the same high byte register again will automatically refresh this stored low byte data. Addr. R/W Register B7 B6 B5 B4 B3 B2 B1 B0 Default 00h R Internal high byte 128 64 32 16 8 4 2 1 00h 29h R Internal low byte 0.5 0.25 0.125 0.0625 Reserved 00h 01h R External channel 1 high byte 128 64 32 16 8 4 2 1 00h 10h R External channel 1 low byte 0.5 0.25 0.125 0.0625 Reserved 00h 23h R External channel 2 high byte 128 64 32 16 8 4 2 1 00h 24h R External channel 2 low byte 0.5 0.25 0.125 0.0625 Reserved 00h Note: R = Read. 12.2. Status register The status register reports the ADC statues and the general error conditions of all channels. Bit 7 (BUSY) indicates that the ADC is currently converting at the time the status register is read. It may be read a “1” or a “0”. To identify specific channels’ error conditions, it is needed to read the external fault register, or High Limit status register, or Low Limit status register, or Therm Limit status register. Once the High Limit, or Low Limit, or Therm Limit register has been read or cleared, all the individual status register bits are cleared and the corresponding status register will be cleared at the same time. Addr. Type Register B7 B6 B5 B4 B3 B2 B1 B0 Default 02h R Status BUSY Reserved HIGH LOW FAULT THERM Reserved 00H (or 80h) Note: R = Read. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |