19 / 24 page ![]() MP5026 – 16V, 20A, 2.8mΩ RDS(ON), HOT-SWAP INTELLI-FUSE SOLUTION MP5026 Rev. 1.0 MonolithicPower.com 19 7/5/2023 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2023 MPS. All Rights Reserved. The device must meet the following conditions to pull the PG signal high and for the system to draw full power: • V OUT > 90% of VIN • V GS > 2V • V OUT > VIN - 0.5V PG indicates low if the device meets any of the following conditions: • V OUT < 75% of VIN • EN/UV is low • Faults occur If a pull-up supply is present without an input, PG remains logic low. Fault Bar (FLTB) Fault bar (FLTB) is an open-drain output that indicate whether a fault has occurred. Pull FLTB up to an external power supply or VCC via a 10k Ω to 100kΩ resistor. FLTB is pulled low with an 8µs propagation delay if any of the following protections are triggered: OCP, SCP, OTP, OVP, or drain-to- source (DS) or gate-to-source (GS) short protection. If any of these fault protections are triggered, FLTB indicates low and latches. After the fault condition is removed, the MP5026 can resume normal operation by cycling the power on VIN, VCC, or EN/UV. If a DS short is detected, FLTB asserts low and holds until VOUT drops below the DS short detection falling threshold. Additional Protections The MP5026 provides additional protections, including OTP, DS short detection, and GS short detection. Over-Temperature Protection (OTP) The MP5026 senses the junction temperature (TJ) internally. Once TJ exceeds 148°C, the power MOSFET shuts down and FLTB indicates low. Drain-to-Source (DS) Short Detection The internal DS short detection circuit starts to work when VIN and VCC exceed their respective UVLO thresholds. Once the device enters tSS, it no longer detects the DS short condition. If VOUT exceeds the smaller value between VIN - 0.5V and 90% of VIN during the detection period, the internal DS short flag is set. If the following conditions are met, a DS short occurs: • Internal DS short flag is set • EN/UV is high • t IDT ends Afterward, FLTB is pulled low, and the GATE voltage remains low to disable the power MOSFET. DS short is a live protection. Once VOUT drops below the smaller value between VIN - 0.7V and 75% of VIN, the device resumes normal operation and FLTB releases high. Gate-to-Source (GS) Short Detection If the following conditions are met, the device determines whether a GS short has occurred and shuts down the power MOSFET: • V GATE < VCP - 0.9V • V SS > VCC - 0.7V • No OC fault has occurred • 200ms delay Where VCP is the charge pump voltage. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |