| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
L9347 bảng dữ liệu(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9347 bảng dữ liệu(HTML) 16 Page - STMicroelectronics |
|
16 / 29 page ![]() Functional Description L9347 16/29 EN&IN=low means that at least one between enable and input is low. For the inputs IN = low means also no input PWM. For the regulator input period longer than TDreg and for the standard channel input period longer thanTD. A detected error is stored in an error register. The reset of this register is made with a timer TD. With this approach all errors are present at the status output at least for the time TD. All protection functions like short circuit of the output, overtemperature, clock failure or power-GND-loss in ON condition are stored into an internal “fail” register. The output is then shut off. The register must be reset with a low signal at the input. A “low signal” means that the input is low for a time longer than TD or TDReg for the reulated channel, otherwise it is interpreted as a PWM input signal and the register is left in set mode. Signal-GND-loss and VS-loss are detected in the active on mode, but they do not set the fail register. This type of error is only delayed with the standard timer t lf function. Open load is detected for all four channels in on and off state. Open load in off condition detects the voltage on the output pin. If this voltage is below 0.33 * VS the error register is set and delayed with TD. A sink current stage pull the output down to ground, with EN high. With EN low the output is floating in case of openload and the detection is not assured. In the ON state the load current is monitored by the non-regulated channels. If it drops below the specified threshold value IQU an open load is detected and the error register is set and delayed with TD. A regulated channel detects the open load in the on state with the current regulator error detection. If the output PWM reaches 90% for a time longer than tRE than an error occurs. This could happen when no load is connected, the Table 7. Detected errors ON State EN &IN = HIGH OFF State EN &IN = LOW Filter time Reset done by Short circuit of the load X tsf EN & IN = “LOW” for TD or TDreg Open load (under voltage detection) Xtlf timer TD Open load (under current detection) Xtsf timer TD Over temperature X tsf EN & IN = “LOW” for TD or TDreg Power-GND-loss X X tlf in on: EN & IN = “LOW” for TD or TDreg in off: timer TD Signal-GND-loss X X tlf timer TD Supply-VS-loss X X tlf timer TD Clock control X X no in on: EN & IN = “LOW” for TD or TDreg in off: timer TD Output voltage clamp active X (regulated channels) no in on: EN & IN = “LOW” for TD or TDreg in off: timer TD |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |