| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LM3556TMX/NOPB bảng dữ liệu(PDF) 19 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM3556TMX/NOPB bảng dữ liệu(HTML) 19 Page - Texas Instruments |
|
19 / 38 page ![]() LM3556 www.ti.com SNVS796D – AUGUST 2011 – REVISED OCTOBER 2015 7.6 Register Maps 7.6.1 Register Descriptions REGISTER NAME INTERNAL HEX ADDRESS POWER ON/RESET VALUE Silicon Revision and Filter Time Register 0x00 0x04 IVFM Mode Register 0x01 0x80 NTC Settings Register 0x02 0x12 Indicator Ramp Time Register 0x03 0x00 Indicator Blinking Register 0x04 0x00 Indicator Period Count Register 0x05 0x00 Torch Ramp Time Register 0x06 0x00 Configuration Register 0x07 0x78 Flash Features Register 0x08 0xD2 Current Control Register 0x09 0x0F Enable Register 0x0A 0x00 Flags Register 0x0B 0x00 7.6.1.1 Silicon Revision and Filter Time Register (0x00) Table 2. Silicon Revision and Filter Time Register Description Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 RFU RFU RFU IVFM Filter Times Bits available for Silicon Revision '00' = 1/2 of the Current Step Time Current Value = '100' '01' = 256 µs '10' =512 µs '11' = 1024 µs 7.6.1.2 Input Voltage Flash Monitor (IVFM) Mode Register (0x01) Table 3. Input Voltage Flash Monitor (IVFM) Mode Register Description Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 1 = UVLO EN Hysteresis Level IVM-D (Down) Threshold IVFM Adjust Mode (default) 00 = 50 mV (default) 000 = 2.9 V (default) 00 = Report Mode (default) 01 = 100 mV 001 = 3 V 01 = Stop and Hold Mode 10 = 150 mV 010 = 3.1 V 10 = Down Mode 11 = Hysteresis Disabled 011 = 3.2 V 11 = Up and Down Mode 100 = 3.3 V 101 = 3.4 V 110 = 3.5 V 111 = 3.6 V 00 = Report Mode Sets IVFM flag in Flags Register upon crossing IVM-D line Only. Does not adjust current. 01 = Stop and Hold Mode Stops current ramp and holds the level for the remaining flash if VIN crosses IVM-D Line. Sets IVFM flag in Flags Register upon crossing IVM-D line. 10 = Down Mode Adjusts current down if VIN crosses IVM-D Line and stops decreasing once VIN rises above the IVM-D line plus the IVFM hystersis setting. The LM3556 decreases the current throughout the flash pulse anytime the input voltage falls below the IVM-D line, and not just once. The flash current does not increase again until the next flash. Sets IVFM flag in Flags Register upon crossing IVM-D Line. 11 = Up and Down Mode Adjusts current down if VIN crosses IVM-D Line and adjusts current up if VIN rises above the IVM-D line plus the IVFM hystersis setting. In this mode, the current continually adjusts with the rising and falling of the input voltage throughout the entire flash pulse. Sets IVFM flag in Flags Register upon crossing IVM-D Line. UVLO EN If enabled and VIN drops below 2.8 V, the LM3556 enters standby and sets the UVLO flag in the Flags Register. Enabled = ‘1’, Disabled = ‘0’ IVM-U = IVM-D + IVFM Hysteresis Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback 19 Product Folder Links: LM3556 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |