21 / 40 page

IBIS5-B-1300 CYII5FM1300AB
Document #: 38-05710 Rev. *C
Page 21 of 40
Windowing in Y-direction
Reapply the Y_START pulse after loading a new Y-pointer value
into the YL_REG and YR_REG registers to load a new Y-pointer
into the Y-shift-register.
Every time a Y_START pulse appears, a frame calibration of the
output amplifier occurs.
Initialization (Start-Up Behavior)
To avoid any high current consumption at start-up, apply the
SYS_CLOCK signal as soon as possible after or even before
power on of the image sensor.
After power on of the image sensor, apply SYS_RESET for a
minimum of five SYS_CLOCK periods to ensure a proper reset
of the on-chip sequencer and timing circuitry. All internal
registers are set to ‘0’ after SYS_RESET is applied.
Since all the IBIS5-B-1300 control signals are active high, apply
a low level (before SYS_RESET occurs) to these pins at start up
to avoid latch up.
Figure 27. Windowing in the Y-Direction