công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

CYII5SC1300AA-HSC bảng dữ liệu(PDF) 13 Page - Cypress Semiconductor

tên linh kiện CYII5SC1300AA-HSC
Giải thích chi tiết về linh kiện  1.3 MP CMOS Image Sensor
PDF  40 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  CYPRESS [Cypress Semiconductor]
Trang chủ  http://www.cypress.com
Logo CYPRESS - Cypress Semiconductor

CYII5SC1300AA-HSC bảng dữ liệu(HTML) 13 Page - Cypress Semiconductor

Back Button CYII5SC1300AA-HSC Datasheet HTML 9Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 10Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 11Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 12Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 13Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 14Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 15Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 16Page - Cypress Semiconductor CYII5SC1300AA-HSC Datasheet HTML 17Page - Cypress Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 40 page
background image
IBIS5-B-1300 CYII5FM1300AB
Document #: 38-05710 Rev. *C
Page 13 of 40
Detailed Description of the Internal Registers
Sequencer register (7:0)
1. Shutter type (bit 0).
The IBIS5-B-1300 image sensor has two shutter types:
0 = synchronous shutter.
1 = rolling shutter.
2. Output amplifier calibration (bits 1 and 2).
Bits FRAME_CAL_MODE and LINE_CAL_MODE define the
calibration mode of the output amplifier.
During every row-blanking period, a calibration is done of the
output amplifier. There are two calibration modes. The FAST
mode (= 0) forces a calibration in one cycle but is not so ac-
curate and suffers from KTC noise. The SLOW mode (= 1)
only makes incremental adjustments and is noise free.
Approximately 200 or more ’slow’ calibrations have the same
effect as one ’fast’ calibration.
Different calibration modes are set at the beginning of the
frame (FRAME_CAL_MODE bit) and for every subsequent
line that is read (LINE_CAL_MODE bit). The Y_START input
defines the beginning of a frame, Y_CLOCK defines the be-
ginning of a new row.
3. Continuous charge (bit 3).
Some applications may require the use continuous charging
of the pixel columns instead of a pre-charge on every line
sample operation.
Setting bit CONT_CHARGE to ’1’ activates this function. The
resistor connected to pin PC_CMD controls the current level
on every pixel column.
4. Internal clock granularities (bits 4, 5, 6 and 7).
The system clock is divided several times on-chip.
Half the system clock rate clocks the X-shift-register that con-
trols the column/pixel readout. Odd and even pixel columns
are switched to two separate buses. In the output amplifier the
pixel signals on the two buses are combined into one pixel
stream at the same frequency as SYS_CLOCK.
Use
the
bits
GRAN_SS_SEQ_MSB
(bit
7)
and
GRAN_SS_SEQ_LSB (bit 6) to program the clock that drives
the ’snapshot’ or synchronous shutter sequencer.
This way the integration time in synchronous shutter mode is
a multiple of 32, 64, 128, or 256 times the system clock period.
To overcome global reset issues, use the longest SS granu-
larity (bits 6 and 7 set to '1').
The clock that drives the X-sequencer is a multiple of 4, 8, 16,
or 32 times the system clock. Clocking the X-sequencer at a
slower rate (longer row blanking time; pixel read out speed is
always equal to the SYSTEM_CLOCK) results in more signal
swing for the same light conditions.
9 (1001)
6:0
DACRAW_REG
Amplifier DAC raw offset
Default value <6:0>: ’1000000’
10 (1010)
6:0
DACFINE_REG
Amplifier DAC fine offset
Default value <6:0>: ’1000000’
11 (1011)
2:0
ADC register
Default value <2:0>: ’011’
0
TRISTATE_OUT
0 = Output bus in tri-state
1
GAMMA
0 = Gamma-correction on
2
BIT_INV
1 = Bit inversion on output bus
12 (1100)
Reserved
13 (1101)
Reserved
14 (1110)
Reserved
15 (1111)
Reserved
Table 10. Internal Registers
(continued)
Register
Bit
Name
Description
Table 11. SS Sequencer Clock Granularities
GRAN_SS_SEQ_MSB/
LSB
SS-Sequencer
Clock
Integration
Time Step[2]
00
32 x SYS_CLOCK
800 ns
01
64 x SYS_CLOCK
1.6
µs
10
128 x SYS_CLOCK
3.2
µs
11
256 x SYS_CLOCK
6.4
µs
Table 12. X Sequencer Clock Granularities
GRAN_X_SEQ_MSB/
LSB
X-Sequencer
Clock
Row Blanking
Time[2]
00
4 x SYS_CLOCK
3.5
µs
01
8 x SYS_CLOCK
7
µs
10
16 x SYS_CLOCK
14
µs
11
32 x SYS_CLOCK
28
µs
Note
2. Using a SYS_CLOCK of 40 MHz (25 ns period).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com