| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
M29DW128F bảng dữ liệu(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29DW128F bảng dữ liệu(HTML) 42 Page - STMicroelectronics |
|
42 / 94 page ![]() Command interface M29DW128F 42/94 6.3.3 Set Extended Block Protection bit command The Set Extended Block Protection bit command programs the Extended Block Protection bit to ‘1’ thus preventing the second section of the Extended Block from being programmed. A Read/Reset command must be issued to abort a Set Extended Block Protection bit command. Six successive steps are required to issue the Set Extended Block Protection bit command. 1. The command starts with two unlock cycles. 2. The third Bus Write cycle sets up the Set Extended Block Protection bit command. 3. The fourth Bus Write Cycle programs the Extended Block Protection bit to ‘1’. 4. The last two cycles verify the value programmed at the Extended Block Protection bit address: if bit DQ0 of Data Inputs/Outputs is set to ’1’, it indicates that the Extended Block Protection bit has been successfully programmed. If DQ0 is ‘0’, the Set Extended Block Protection bit command must be issued and verified again. 6.3.4 Verify Extended Block Protection bit command The Verify Extended Block Protection bit command reads the status of the Extended Block Protection bit on bit DQ0 of the Data Inputs/Outputs. If DQ0 is ‘1’, the second section of the Extended Block is protected from program operations. 6.3.5 Password Program command The Password Program Command is used to program the 64-bit Password used in Password Protection mode. Four cycles are required to program the Password: 1. The first two cycles are unlock cycles. 2. The third cycle issues the Password Program command. 3. The fourth cycle inputs the 16-bit data required to program the Password. To program the 64-bit Password, the complete command sequence must be entered four times at four consecutive addresses selected by A1 to A0. Read operations can be used to read the Status Register during a Password Program operation. All other operations are forbidden. The Password can be checked by issuing a Password Verify command. Once Password Program operation has completed, a Read/ Reset command must be issued to return the device to Read mode. The Password Protection mode can then be selected. By default, all Password bits are set to ‘1’. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |