| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MC34653EF/R2 bảng dữ liệu(PDF) 14 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MC34653EF/R2 bảng dữ liệu(HTML) 14 Page - Freescale Semiconductor, Inc |
|
14 / 24 page ![]() Analog Integrated Circuit Device Data 14 Freescale Semiconductor 34653 FUNCTIONAL DEVICE OPERATION PROTECTION AND DIAGNOSIS FEATURES PROTECTION AND DIAGNOSIS FEATURES UNDERVOLTAGE When the input voltage drops below the undervoltage falling threshold for more than 1.0 ms, an undervoltage fault is detected and one of the start-up conditions (list on page 10) is violated. The 34653 turns off the Power MOSFET and deactivates the power good output signals, disabling the load (Point A in Figure 14). The 34653 stays in this state until the input voltage rises above the undervoltage rising threshold for more than 1.0 ms, signaling that the supply voltage is in the normal operation range (Point B in Figure 14). Then a new start-up sequence initiates as described on page 10. The undervoltage detection circuit is also equipped with a 1.0 V hysteresis. Figure 14. Undervoltage Fault Followed by a New Start-Up Sequence Figure 15 shows how the 34653 uses the start-up timer to make sure that the input voltage is above the undervoltage falling threshold. The 34653 was in normal operation before Point A. At Point A an undervoltage fault occurs. Then the fault is cleared at Point B, and the 34653 initiates a start-up sequence. Before the end of the start-up timer another undervoltage fault occurs at Point C, so the 34653 does not turn on the Power MOSFET. At Point D the fault is cleared again for the length of the start-up timer and the 34653 turns on the Power MOSFET and starts the charging process (refer to Charging Process, pages 10–11). Figure 15. Start-Up Timer Protection Against Undervoltage Faults OVERVOLTAGE When the input voltage exceeds the overvoltage rising threshold for more than 1.0 ms, an overvoltage fault is detected and one of the start-up conditions (list on page 10) is violated. The 34653 turns off the Power MOSFET and deactivates the power good output signals, disabling the load. The 34653 stays in this state until the input voltage falls below the overvoltage falling threshold for more than 1.0 ms, signaling that the supply voltage is in the normal operation range. Then a new start-up sequence initiates as described on page 10. The overvoltage detection circuit is also equipped with a 2.0 V hysteresis. The waveforms for an overvoltage fault are shown in Figure 16. Figure 16. Overvoltage Fault |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |