20 / 46 page ![]() CS5464 20 DS682PP1 rent registers. The maximum pulse frequency from the E1 pin is (MCLK/K)/2048. 5.5.4 Voltage Channel Sign Mode Setting bits E3MODE[1:0] = 2 (10b) in the Operational Mode Register outputs the sign of the voltage channel on pin E3. Figure 8 illustrates the output format with volt- age channel sign on E3. Output pin E3 is high when the line voltage is positive and pin E3 is low when the line voltage is negative. 5.5.5 PFMON Output Mode Setting bit E3MODE[1:0] = 1 (01b) in the Operational Mode Register outputs the state of the PFMON compar- ator on pin E3. Figure 9 illustrates the output format with PFMON on E3. When PFMON is greater than the threshold, pin E3 is high and when PFMON is less than the threshold pin E3 is low. 5.5.6 Design Example EXAMPLE #1: The maximum rated levels for a power line meter are 250 V rms and 20 A rms. The required number of puls- es-per-second on E1 is 100 pulses per second (100 Hz), when the levels on the power line are 220 V rms and 15 A rms. With a 10x gain on the voltage and current channel the maximum input signal is 250 mVP. (See Section 5.1 An- alog Inputs on page 17.) To prevent over-driving the channel inputs, the maximum rated rms input levels will register 0.6 in VRMS and IRMS by design. Therefore the voltage level at the channel inputs will be 150 mV rms when the maximum rated levels on the power lines are 250 V rms and 20 A rms. Solving for PulseRateE using the transfer function: Therefore with PF = 1 and: the pulse rate is: and the PulseRateE Register is set to: with MCLK = 4.096 MHz and K = 1. 5.6 Sag and Fault Detect Feature Status bit VSAG (V2SAG) and IFAULT (I2FAULT) in the Status Register, indicates a sag occurred in the power line voltage (voltage 2) and current (current 2), respec- tively. For a sag condition to be identified, the absolute value of the instantaneous voltage or current must be less than the sag level for more than half of the sag du- ration (see Figure 10). To activate voltage sag detection, a voltage sag level must be specified in the Voltage Sag Level Register (VSAGlevel, V2SAGlevel), and a voltage sag duration must be specified in the Voltage Sag Duration Register (VSAGduration, V2SAGduration). To activate current fault detection, a current sag level must be specified in the Current Fault Level Register (ISAGlevel, I2SAGlevel), and a current sag duration must be specified in the Current Fault Duration Register (ISAGduration, I2SAGduration). The voltage and current sag levels are specified as the average of the absolute instantaneous voltage and cur- rent, respectively. Voltage and current sag duration is specified in terms of ADC cycles. E3 E2 E1 Figure 8. Voltage Channel Sign Pulse outputs E3 E2 E1 Above PFMON Threshold Below PFMON Threshold Figure 9. PFMON output to pin E3 PulseRate FREQ P VREFIN 2 × VIN VGAIN × IIN × IGAIN PF × × --------------------------------------------------------------------------------------------- = VIN 220V 150mV () 250V () ⁄ () × 132mV == IIN 15A 150mV () 20A () ⁄ () × 112.5mV == PulseRate 100 2.5 2 × 0.132 10 × 0.1125 × 10 × ----------------------------------------------------------------- 420.8754Hz == PulseRateE PulseRate MCLK K ⁄ () 2048 ⁄ ---------------------------------------- 0.2104377 == Level Duration Figure 10. Sag and Fault Detect |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |