138 / 264 page ![]() Inductive sensor interface L9788 138/264 DS12308 Rev 4 according to the new selection programmed) not synchronized with any VRS_FB zero crossing. 11.2.2 VRS_A - Manual Hysteresis To set the manual hysteresis on VRS_A configuration, bit VRS_MODE[0] has to be configured at '0'. Hysteresis value is manually set through VRS_HYST[2:0] of CONFIG- REG 8 according to Table 58. Such hysteresis is fixed until a new SPI programming occurs. Default hysteresis current after exiting reset is HI3. New MSC current value is updated during HYST CURRENT OFF phase that means the output comparator is high. Table 58. VRS_A hysteresis value Hysteresis current [H] Min Typ Max Unit Correspondent value on 20 kΩ ext. resistor Unit HI1 3 5 7 µA 100 mV HI2 7.5 10 13.5 µA 200 mV HI3 13 17 23 µA 347 mV HI4 23 32 40 µA 644 mV HI5 35 51 60 µA 1020 mV No Hyst - - - - - - |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|