50 / 264 page ![]() Watchdog L9788 50/264 DS12308 Rev 4 "… within the time window" means that the end of writing the last answer byte - i.e. RESP_BYTE0 - falls into the fixed time window mentioned above (see picture below). Except the last answer byte, the previous answer bytes may also be written earlier than the beginning of the fixed time window. The question sequence is deterministic. A question will be repeated until it is answered correctly both in value and in time. Then the next question is placed in the sequence. The ERROR COUNTER (EC) is a 3-bit counter. Various actions are activated depending on the value of the counter. The result of the comparison of the controller response and the calculated correct response, as well as the next question, are available in registers REQULO after receiving the µC response (LSB of RESP_BYTE0) and can be read by the controller. Figure 19. Monitoring cycle diagram 4.1.2 ERR CNT (EC) and reactions, PWR COUNTER (PWR_CNT) and generation of the monitoring module reset Various actions are initiated for specific counter states of the ERROR COUNTER EC. The counter reset state is 6. For ERROR COUNTER (EC) > 4, the open drain output WDA is pulled low (active). If the ERROR COUNTER reaches the value “7” and a further error occurs the PWR_CNT is incremented by one during a sequencer-run. The state "EC = 7 and a further error occurs" is also called ERROR COUNTER overflow ("EC" > 7). start monitor cycle CPU response end of writing RESP_BYTE0 starts next monitor cycle GADG2511161221PS 1.6 ms < response time window < 100.8 ms @ 64 kHz ±5% time window = 12.8 ms @ 64 kHz ±5% Table 19. Error counter ERR_CNT 0 … 4 5 6 … 7 Overflow ERR_CNT > 7 WDA Hi-Z Low Low Low PWR_CNT 0 unchanged unchanged Incremented by 1 Internal PWR_CNT signal Low (not active) If PWR_CNT = 7 and ERR_CNT increase => High (active) Else unchanged If PWR_CNT = 7 and ERR_CNT increase => High (active) Else unchanged PWR_CNT < 7 Low (inactive) PWR_CNT 6->7 Low (inactive) PWR_CNT 7 -> 7 High (active) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |