51 / 264 page ![]() DS12308 Rev 4 51/264 L9788 Watchdog 263 The counter PWR_CNT is a 3 bit counter. Behaviour of PWR_CNT: asynchronous reset to "000" with RST_UV synchronous reset to "000" IF (EC < 5) IF (PWR_CNT < 7) AND (sequencer-run AND "EC" > 7) THEN PWR_CNT = PWR_CNT + 1 ELSE unchanged. The counter cannot be decremented and can be only reset to "000" by an active RST_UV signal (asynchronous) or <WDA_INT> = '0' (synchronous).The signal PWR_INT becomes active '1' when PWR_CNT = "111" and a further error is detected. When KEY_IN =0, the active PWR_INT signal causes a shut-down of the main relay and the voltage regulators. This function ensures a secure shutdown of the system in an error state of the µC in "power- latch". Signal PWR_INT is set to '0' again only when <WDA_INT> = '0'. 4.1.3 Generation of a monitoring module reset The monitoring module may cause a reset at the pin [RSTN] named "monitoring module reset" in conjunction with the internal signal WDA_RST. The generation of a monitoring module reset depends on the state of the bit <WDA_INT>. < WDA_INT> = '0' (reset state): If < WDA_INT> = '0', the signal <WDA_RST> remains always inactive '0' and the monitoring module can never generate a reset. The error counter can only be decremented via correct responses. If < WDA_INT> = '0' the state of the reset counter <RST_CNT> remains unchanged when an ERROR COUNTER overflow occurs (description of the reset counter <RST_CNT> see below). < WDA_INT> = '1': If < WDA_INT> = '1', an ERROR COUNTER overflow activates a reset [RST] (signal <WDA_RST> becomes active). The signal <WDA_RST> becomes active (i.e. '1') due to an ERROR COUNTER overflow when the value of the 3 bit reset counter <RST_CNT(2-0)> is 0..6. If the value of <RST_CNT> = "111" and an ERROR COUNTER overflow occurs <WDA_RST> remains inactive (i.e. '0') and no reset is generated. The "reset counter" <RST_CNT> is incremented by one during a sequencer-run due to an ERROR COUNTER overflow when < WDA_INT> = '1' and <RST_CNT> is between 0 and 6. If <RST_CNT> = 7 and an ERROR COUNTER overflow occurs, the counter state remains 7. The counter can not be decremented and can only reset to zero by an active RST_UV signal. The occurrence of a monitoring module reset is indicated via the flag <WDA_RST> = '1'. Reading the flag via MSC clears it automatically. In effect maximum 7 monitoring module resets can be generated between 2 active RST_UV signal. (see also state table for < WDA_INT> = '1' below).The state of the "reset counter" <RST_CNT> can be read via MSC but cannot be changed. Table 20. Internal states for WDA_INIT=1 RST_CNT old value EC>7 and sequencer-run RST_CNT new value WDA_RST 000 … 111 False = RST_CNT old 0, no monitoring module reset 000 … 110 True = RST_CNT old + 1 1, monitoring module reset generated 111 True = 111 0, no monitoring module reset |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |