28 / 73 page ![]() Functional description L99LD21 28/73 DS11130 Rev 5 4.3.5 Buck output’s short circuit to GND A shorted buck output to GND is detected when LED string voltage (VLED) is lower than a specified threshold (VLED_SHT) and the corresponding failure counter counts Nton_min_fail switching cycles (also nonconsecutive), during which ILx_PEAK is reached between TBLANK_BUCK and TON_MIN_BUCK. In normal mode (Active mode), once a short circuit is validated, flag SHTx is set and the corresponding Buckx converter is latched off, until the microcontroller sends a frame and clears the corresponding status bit (SR#1<7> and SR#1<6>). In fail safe mode (Limp Home), once a short circuit is validated, the corresponding buck converter is latched off until automatically cleared by an auto-restart procedure, with a period equal to tAUTORESTART. The failure counter is not incremented during the startup phase. The failure counter is reset if Nton_min_fail_reset consecutive pulses are detected with TON longer than TON_MIN_BUCK. 4.3.6 Buck TON maximum operation Buck maximum on time operation is detected when switching on time is equal to tON_MAX_BUCK for two consecutive cycles. Once maximum Ton operation is validated, flag TON_MAX_OPx is set and the corresponding Buckx converter is temporarily switched off for a Ttonmax_off. Then, Buckx is enabled to switch on again while TON_MAX_OPx bit will be latched until a R&C command clears corresponding status bit (SR#2<20> or SR#2<19>). In fail safe mode (Limp Home), once a maximum TON violation is validated, the corresponding buck converter is latched off until automatically cleared by an auto-restart procedure, with a period equal to tAUTORESTART. 4.3.7 Buck Open Load detection If one of the LED strings is disconnected, the converter will charge the output capacitor of the buck converter by regulating the peak current of the switch, until VLED is equal to the buck input voltage. From this point, since the output capacitor is charged at the maximum possible value, it cannot absorb any current despite the activation of the switch, and the target ILx_PEAK cannot be reached. Upon these conditions, Buckx starts switching at maximum Ton: maximum Ton operation detection (described in Section 4.3.6) guarantees Open Load failure protection as well. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |