| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
L9780 bảng dữ liệu(PDF) 37 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9780 bảng dữ liệu(HTML) 37 Page - STMicroelectronics |
|
37 / 56 page ![]() DocID026356 Rev 3 37/56 L9780 Digital interface description 55 Bit 31: STBHTH This bit selects the heater short to battery threshold as follows: STBHTH=’0’ => 250 mV; STBHTH=’1’ => 425 mV; The possible ranges of these thresholds are specified in Table 13. If the device receives an SPI command in order to modify STBHTH bit in the middle of a measurement cycle, it stores the new information and applies it at the beginning of the new measurement cycle. STBHTH bit value reported in the output register is the value used in the last measurement cycle. Default state for this bit after power on reset: 0. Bit 30 - 24: ITPT[6..0] These bits are used to set the RCT1 switch time pulse duration (tR), as specified in section Table 16. If the device receives a configuration ITPT[6..0]=’0011000’ or less (except 0000000), the device considers this configuration as ‘0011001’, and shall provide SO response with the configuration received from SI, even if is ‘0011000’ or less. If the device receives an SPI command in order to modify ITPT[6..0] bits in the middle of a measurement cycle, it stores the new information and applies it at the beginning of the new measurement cycle. ITPT[6..0] bits reported in the output register are the values used in the last measurement cycle. For the description of the timing sequence refer to Section 4.12. Default state for these bits after power on reset: 0000000 (corresponding to disable state). Bit 23: SNC This bit selects the synchronized mode for the device (when SNC=’1’) or the free running mode (when SNC=’0’). If the device receives an SPI command in order to set SNC=’1’ bit in the middle of a measurement cycle, it terminates the measurement cycle and discards all the temporary conversions; then operates in idle configuration until a rising edge on SY pin is detected; this is the signal necessary to start a new measurement cycle and to clear the measurement counter. Default state for this bit after power on reset: 0. Bit 22 - 16: CBT[6..0] These bits are used to set the RCT1 band-gap switch time pulse duration (tB), as specified in Table 16. If the device receives an SPI command in order to modify CBT[6..0] bits in the middle of a measurement cycle, it stores the new information and applies it at the beginning of the new measurement cycle. CBT[6..0] bits reported in the output register are the values used in the last measurement cycle. For the description of the timing sequence refer to Section 4.12. Default state for these bits after power on reset: 0000000. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |