| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
DMX250 bảng dữ liệu(PDF) 13 Page - Yamar Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
DMX250 bảng dữ liệu(HTML) 13 Page - Yamar Electronics Ltd. |
|
13 / 28 page ![]() Data may be changed without notice - Proprietary information of Yamar Electronics Ltd. ©2019-2022 Yamar Electronics Ltd. 13 DS-DMX250 R 0.80 www.yamar.com Tel: +972-3-5445294 Fax: +972-3-5445279 3.5 DMX250 UUID Each DMX250 device is hard-coded with a 48 bit universally unique identifier (UUID[47:0]). The UUID is stored in REG_59 to REG_5E and can be retrieved using the READ-REG commands (see 5.4 to 5.95.9). 3.6 DMX interface typical set-up and operation 1. Interface HDI, HDO, and HDC (Optional) pins. 2. Select a carrier frequency (default 13MHz) (see 3.4). 3. Transmit data bytes via HDI pin to the powerline. 4. Receive data bytes from the powerline via HDO pin. 3.7 DMX Examples 3.7.1 DMX Example 1 - Typical communication flow Figure 13 depicts a typical TX-RX DMX message flow. The DMX-controller starts a new message with a break signal, followed by start code and data bytes on DMX250 HDI. Upon detection of the break signal, the DMX250 initiates the DMX frame over the powerline. After a fixed latency of ~100usec, the DMX250 RX device output on HDO the break signal, followed by the start code and message received data bytes. Figure 13 - DMX typical communication sequence 3.7.2 DMX Example 2 - WRITE-REG command Figure 14 depicts a WRITE-REG command sequence. First, the HDC is pulled low and the device enters the Command mode. The DMX-controller sends the write command with the 1 st byte of 0xF5, followed by the control register address byte (A[7:0]), and then the data byte to be written (B[7:0]). After completing the write sequence, the HDC pin is pulled high and the device returns to Normal mode. Figure 14- DMX Write Register command sequence 3.7.3 DMX Example 3 - READ-REG command Figure 15 depicts a READ-REG command sequence. First, the HDC is pulled low and the device enters the Command mode. The user sends the read command with the 1 st byte of 0xFD, followed by the control register address byte (A[7:0]). Then the DMX-controller receives the register internal value (B[7:0]). The HDC pulled back to high and the device returns to Normal mode. Figure 15 - DMX Read Register command sequence |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |