11 / 14 page ![]() 11 sensing.honeywell.com ±50 SCCM to ±750 SCCM D lgital Interface For additional details on the use of Zephyr with digital output see the Technical Note “I2C Communications with Honeywell Digital Airflow Sensors”. The sensor uses the I2C standard for digital communication with a slave address specified in the Nomenclature and Order Guide in Figure 4. Following sensor power-up, each of the first two read sequences shown in Figure 9 will respond with 2 bytes of the unique 4-byte Serial Number. The first read after power-up will respond with the two most significant bytes of the Serial Number, while the second read will respond with the two least significant bytes of the Serial Number. For reliable performance, allow sensor to be powered for the sensor start-up time before performing the first read, then allow a 10 ms command response time before performing the second read. After the power-up read sequence described above, the sensor will respond to each I2C read request with a 16-bit (2 byte) digital flow reading. Read requests taken faster than the Response Time (1 ms) are not guaranteed to return fresh data. The first two bits of each flow reading will be ‘00’. The maximum sink current on SCL or SDA is 2 mA. Therefore, if the pull-up resistors are biased by V DD, and if VDD reaches the maximum supply voltage of 6 V, then the pull-up resistors for SCL and SDA must be greater than 3.0 kΩ to limit the sink current to 2 mA. The typical value for SCL and SDA pull-up resistors is 4.7 kΩ (this value depends on the bus capacitance and the bus speed). Figure 9. Sensor I2C read and Write Sequences Start condition S A6 A5 A4 A3 A0 A2 A1 1 SA D7 D6 D5 D3 D2 D1 D0 MA D6 D4 D3 D2 D1 D0 MN S D4 D5 D7 SDA SCL S A6 A5 A4 A3 A0 A2 A1 1 SA D7 D6 D5 D3 D2 D1 D0 MA S D4 SDA SCL Stop condition Address bit Read/write bit Data bit Slave ACK Master ACK Master NACK S S D7 A6 1 SA MA MN Master pulls SDA from high to low while SCL remains high Master allows SDA to float from low to high while SCL remains high I2C Slave Address is the 7 Most Significant Bits for the first transmitted byte Read = 1, Write = 0 Slave pulls SDA low Master pulls SDA low Master allows SDA to float high I2C Read: Slave responds to Master with data Data Byte 0 (Most Significant) Data Byte 1 (Least Significant) Command Byte I2C Read: Master sends data to Slave Bit Name Description |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |