công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

HAFBLF0100C5ACAAX3 bảng dữ liệu(PDF) 6 Page - Honeywell Solid State Electronics Center

tên linh kiện HAFBLF0100C5ACAAX3
Giải thích chi tiết về linh kiện  HAF Series?밐igh Accuracy
PDF  14 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  HONEYWELL [Honeywell Solid State Electronics Center]
Trang chủ  http://honeywell.com/Pages/Home.aspx
Logo HONEYWELL - Honeywell Solid State Electronics Center

HAFBLF0100C5ACAAX3 bảng dữ liệu(HTML) 6 Page - Honeywell Solid State Electronics Center

Back Button HAFBLF0100C5ACAAX3 Datasheet HTML 2Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 3Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 4Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 5Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 6Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 7Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 8Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 9Page - Honeywell Solid State Electronics Center HAFBLF0100C5ACAAX3 Datasheet HTML 10Page - Honeywell Solid State Electronics Center Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 14 page
background image
6
sensing.honeywell.com
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series–High Accuracy
CAUTION
IMPROPER USE
Do not use these products to sense liquid flow.
Failure to comply with these instructions may result in
product damage.
Table 1. Absolute Maximum ratings1
Characteristic
Parameter
Supply voltage
-0.3 Vdc to 6.0 Vdc
Voltage on I/O output pin
-0.3 Vdc to Vsupply
Storage temperature range
-40 °C to 125 °C [-40 °F to 257 °F]
Maximum flow change
5.0 SLPM/s
Maximum common mode pressure
25 psi at 25 °C [77 °F]
Maximum flow
10 SLPM
1
Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings.
CAUTION
PRODUCT DAMAGE
Do not disassemble these products.
Failure to comply with these instructions may result in
product damage.
Table 2. operating Specifications
Characteristic
Parameter
notes
Supply voltage
3.3 Vdc
5.0 Vdc
3.3 Vdc ±10%
5.0 Vdc ±10%
—
Power:
3.3 Vdc
5.0 Vdc
40 mW max.
65 mW max.
1
Compensated temperature range
0 °C to 50 °C [32 °F to 122 °F]
2
Operating temperature range
-20 °C to 70 °C [-4 °F to 158 °F]
—
Accuracy
See Table 3.
3, 4
Total Error Band (TEB)
See Table 3.
4, 5
Null accuracy
0.1 %FSS
4, 6
Response time
1 ms typ.
7
Resolution
12 bit min.
—
Start-up time
17 ms
8
Warm-up time
30 ms
9
Calibration media
gaseous nitrogen
10
Bus standards
I2C fast mode (up to 400 kHz)
11
Null stability
Null will not deviate beyond the specified TEB.
—
Reverse polarity protection
no
—
1
Maximum Power: Is measured under the conditions of the highest supply voltage Vsupply + 10%, 70° C, full scale flow and with the minimum pull-up resistors for SDA and SCL
according to the I2C specification.
2
Custom and extended compensated temperature ranges are possible. Contact Honeywell for details.
3
Accuracy: The maximum deviation from the nominal digital output over the compensated flow range at a reference temperature of 25 °C. Errors include offset, span, non-linearity,
hysteresis and non-repeatability.
4
Full Scale Span (FSS): The algebraic difference between the digital output at the forward Full Scale (FS) flow and the digital output at the reverse FS flow. Forward flow is defined as
flow from P1 to P2 as shown in Figure 4. The references to mass flow (SCCM) refer to gas flows at the standard conditions of 0 °C and atmospheric pressure 760 (101.3 kPa).
5
Total Error Band (TEB): The maximum deviation in output from ideal transfer function over the entire compensated temperature and flow range. Includes all errors due to offset, full
scale span, flow hysteresis, flow repeatability, thermal effect on offset, thermal effect on span and thermal hysteresis.
6
Null accuracy: The the maximum deviation in output at 0 SCCM from the ideal transfer function over the compensated temperature range. This includes offset errors, thermal airflow
hysteresis and repeatability errors.
7
Response time: The time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer may be affected by the pneumatic
interface).
8
Start-up time: The time to first valid reading of serial number proceeding streaming 14-bit flow measurements.
9
Warm-up time: The time to the first valid flow measurement after power is applied.
10
Default calibration media is dry nitrogen gas. Please contact Honeywell for other calibration options.
11
Refer to the Technical Note “I2C Communications with Honeywell Digital Airflow Sensors” for I2C protocol information.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com