80 / 138 page ![]() 3.3v I/O Controller for Port Replicators and Docking Stations Revision 0.3 (10-26-04) Page 80 SMSC DS – LPC47N237 DATASHEET Table 15.1 – SMBus Pins PIN NAME TYPE PWR WELL DESCRIPTION SMB_A0 I VTR SMBus LSB address pin with SCLK IOD VTR SMBus Clock IOD SDAT IOD VTR SMBus Data IOD nSMBINT OD VTR Active low SMBus Interrupt Open-Drain output SCLK_1 IOD VTR SMBus Clock IOD SDAT_1 IOD VTR SMBus Data IOD SCLK_2 IOD VTR SMBus Clock IOD SDAT_2 IOD VTR SMBus Data IOD 15.1.2 Bus Protocols Typical Write Byte, Read Byte protocols are shown below. Register accesses are performed using 7-bit slave addressing, an 8-bit register address field, and an 8-bit data field. The shading indicates the LPC47N237 driving data on the SDAT line; otherwise host data is on the SDAT line. The slave address is the unique SMBus Interface Address for the LPC47N237 that identifies it on SMBus. The register address field is the internal address of the register to be accessed. The register data field is the data that the host is attempting to write to the register or the contents of the register that the host is attempting to read. Data bytes are transferred MSB first. When using the LPC47N237 SMBus Interface, a read and write will always consist of the SMBus Interface Address byte, followed by the Register Address byte, then the data byte. Write Byte The Write Byte protocol is used to write data to the registers. The data will only be written if the protocol shown in Table 15.2 is performed correctly. Only one byte is transferred at time for a Write Byte protocol. Table 15.2 − SMBus Write Byte Protocol Field: Start Slave Addr Wr Ack Reg. Addr Ack Reg. Data Ack Stop Bits: 1 7 1 1 8 1 8 1 1 Read Byte The Read Byte protocol is used to read data from the registers. The data will only be read if the protocol shown in Table 15.3 is performed correctly. Only one byte is transferred at time for a Read Byte protocol. Table 15.3 − SMBus Read Byte Protocol Field: Start Slave Addr Wr Ack Reg. Addr Ack Start Slave Addr Rd Ack Reg. Data Nack Stop Bits: 1 7 1 1 8 1 1 7 1 1 8 1 1 15.1.3 Slave Address The slave address is the unique address for the LPC47N237 that identifies the device on SMBus. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |