105 / 112 page ![]() Data Sheet ADF7023 Rev. C | Page 105 of 112 Table 122. 0x345: RXBB_CAL_CALWRD_READBACK Bit Name R/W Reset Description [5:0] RXBB_CAL_CALWRD R 0 RXBB reference oscillator calibration word; valid after RXBB calibration cycle has been completed. Table 123. 0x346: RXBB_CAL_CALWRD_OVERWRITE Bit Name R/W Reset Description [6:1] RXBB_CAL_DCALWRD_OVWRT_IN RW 0 RXBB reference oscillator calibration overwrite word [0] RXBB_CAL_DCALWRD_OVWRT_EN RW 0 1: enable RXBB reference oscillator calibration word overwrite mode 0: disable RXBB reference oscillator calibration word overwrite mode Table 124. 0x34F: RCOSC_CAL_READBACK_HIGH Bit Name R/W Reset Description [7:0] RCOSC_CAL_READBACK[15:8] R 0x0 Fine RC oscillator calibration result, Bits[15:8] Table 125. 0x350: RCOSC_CAL_READBACK_LOW Bit Name R/W Reset Description [7:0] RCOSC_CAL_READBACK[7:0] R 0x0 Fine RC oscillator calibration result, Bits[7:0] Table 126. 0x359: ADC_CONFIG_LOW Bit Name R/W Reset Description [7:4] Reserved R/W 0 Set to 0. [3:2] ADC_REF_CHSEL R/W 0 0: RSSI (default). 1: external AIN 2: temperature sensor 3: unused [1:0] ADC_REFERENCE_CONTROL R/W 0 The following reference values are valid for a 3 V supply: 0: 1.85 V (default) 1: 1.95 V 2: 1.75 V 3: 1.65 V Table 127. 0x35A: ADC_CONFIG_HIGH Bit Name R/W Reset Description [7] Reserved R/W 0 [6:5] FILTERED_ADC_MODE R/W 0 Filtering modes. 00: normal operation (no filter). 01: unfiltered AGC loop, filtered readback (updated upon MCR read). 10: unfiltered AGC loop, filtered readback (update at AGC clock rate). 11: filtered AGC loop, filtered readback. [4] ADC_EXT_REF_ENB R/W 1 Bring low to power down the ADC reference. [3:0] Reserved R/W 1 Set to 1. Table 128. 0x35B: AGC_OOK_CONTROL Bit Name R/W Reset Description [5:3] OOK_AGC_CLK_TRK R/W 2 AGC update rate during tracking phase 1) ( 2 + = K_TRK OOK_AGE_CL MAN F Rate Update AGC where F MAN= the Manchester symbol rate. Manchester encoding is recommended for OOK; OOK_AGC_CLK_TRK must be ≥ OOK_AGC_CLK_ACQ. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |