| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
EVAL-ADF7023DB2Z bảng dữ liệu(PDF) 73 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
EVAL-ADF7023DB2Z bảng dữ liệu(HTML) 73 Page - Analog Devices |
|
73 / 112 page ![]() Data Sheet ADF7023 Rev. C | Page 73 of 112 RADIO BLOCKS FREQUENCY SYNTHESIZER A fully integrated RF frequency synthesizer is used to generate both the transmit signal and the receiver’s local oscillator (LO) signal. The architecture of the frequency synthesizer is shown in Figure 107. The receiver uses a fractional-N frequency synthesizer to generate the mixer’s LO for down conversion to the intermediate frequency (IF) of 200 kHz or 300 kHz. In transmit mode, a high resolution sigma-delta (Σ-Δ) modulator is used to generate the required frequency deviations at the RF output when FSK data is transmitted. To reduce the occupied FSK bandwidth, the transmitted bit stream can be filtered using a digital Gaussian filter, which is enabled via the RADIO_CFG_9 register (Address 0x115). The Gaussian filter uses a bandwidth time (BT) of 0.5. The VCO and the PLL loop filter of the ADF7023 are fully integrated. To reduce the effect of pulling of the VCO by the power-up of the PA and to minimize spurious emissions, the VCO operates at twice or four times the RF frequency. The VCO signal is then divided by 2 or 4, giving the required frequency for the transmitter and the required LO frequency for the receiver. A high speed, fully automatic calibration scheme is used to ensure that the frequency and amplitude characteristic of the VCO are maintained over temperature, supply voltage, and process variations. The calibration is automatically performed when the CMD_PHY_RX or CMD_PHY_TX command is issued. The calibration duration is 142 µs, and if required, the CALIBRATION_STATUS register (Address 0x339) can be polled to indicate the completion of the VCO self-calibration. After the VCO is calibrated, the frequency synthesizer settles to within ±5 ppm of the target frequency in 56 µs. Figure 107. RF Frequency Synthesizer Architecture Synthesizer Bandwidth The synthesizer loop filter is fully integrated on chip and has a programmable bandwidth. The communications processor automatically sets the bandwidth of the synthesizer when the device enters PHY_TX or PHY_RX state. On entering the PHY_TX state, the communications processor chooses the bandwidth based on the programmed modulation scheme (2FSK, GFSK, or OOK) and the data rate. This ensures optimum modulation quality for each data rate. On entering the PHY_RX state, the communications processor sets a narrow bandwidth to ensure best receiver rejection. In all, there are eight bandwidth configurations. Each synthesizer bandwidth setting is described in Table 30. Table 30. Automatic Synthesizer Bandwidth Selections Description Data Rate (kbps) Closed Loop Synthesizer Bandwidth (kHz) Rx 2FSK/GFSK/MSK/GMSK All 92 Tx 2FSK/GFSK/MSK/GMSK 1 to 49.5 130 Tx 2FSK/GFSK/MSK/GMSK 49.6 to 99.1 174 Tx 2FSK/GFSK/MSK/GMSK 99.2 to 129.5 174 Tx 2FSK/GFSK/MSK/GMSK 129.6 to 179.1 226 Tx 2FSK/GFSK/MSK/GMSK 179.2 to 239.9 305 Tx 2FSK/GFSK/MSK/GMSK 240 to 300 382 Tx OOK All 185 Synthesizer Settling After the VCO calibration, a 56 μs delay is allowed for synthesizer settling. This delay is fixed at 56 μs by default and ensures that the synthesizer has fully settled when using any of the default synthesizer bandwidths. However, in some cases, it may be necessary to use a custom synthesizer settling delay. To use a custom delay, set the CUSTOM_TRX_SYNTH_LOCK_TIME EN bit to 1 in the MODE_CONTROL register (Address 0x11A). The synthesizer settling delays for the PHY_RX and PHY_TX state transitions can be set independently in RX_SYNTH_LOCK_TIME register (Address 0x13E) and the TX_SYNTH_LOCK_TIME register (Address 0x13F). The settling time can be set in the range 2 μs to 512 μs in steps of 2 μs. Bypassing VCO Calibration It is possible to bypass the VCO calibration for ultrafast frequency hopping in transmit or receive. The calibration data for each RF channel should be stored in the host processor memory. The calibration data comprises two values: the VCO band select value and the VCO amplitude level. Read and Store Calibration Data 1. Go to the PHY_TX or PHY_RX state without bypassing the VCO calibration. 2. Read the following MCR registers and store the calibrated data in memory on the host processor: a. VCO_BAND_READBACK (Address 0x3DA) b. VCO_AMPL_READBACK (Address 0x3DB) F_DEVIATION RF FREQ LOOP FILTER VCO 26MHz REF TX DATA FRAC-N INTEGER-N N DIVIDER VCO CALIBRATION Σ-Δ DIVIDER GAUSSIAN FILTER PFD CHARGE PUMP ÷2 OR ÷4 ÷2 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |