Back Button EVAL-ADF7023DB2Z Datasheet HTML 69Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 70Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 71Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 72Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 73Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 74Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 75Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 76Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 77Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 73 / 112 page
background image
Data Sheet
ADF7023
Rev. C | Page 73 of 112
RADIO BLOCKS
FREQUENCY SYNTHESIZER
A fully integrated RF frequency synthesizer is used to generate
both the transmit signal and the receiver’s local oscillator (LO)
signal. The architecture of the frequency synthesizer is shown in
Figure 107.
The receiver uses a fractional-N frequency synthesizer to generate
the mixer’s LO for down conversion to the intermediate frequency
(IF) of 200 kHz or 300 kHz. In transmit mode, a high resolution
sigma-delta (Σ-Δ) modulator is used to generate the required
frequency deviations at the RF output when FSK data is
transmitted. To reduce the occupied FSK bandwidth, the
transmitted bit stream can be filtered using a digital Gaussian filter,
which is enabled via the RADIO_CFG_9 register (Address 0x115).
The Gaussian filter uses a bandwidth time (BT) of 0.5.
The VCO and the PLL loop filter of the ADF7023 are fully
integrated. To reduce the effect of pulling of the VCO by the
power-up of the PA and to minimize spurious emissions, the VCO
operates at twice or four times the RF frequency. The VCO signal
is then divided by 2 or 4, giving the required frequency for the
transmitter and the required LO frequency for the receiver.
A high speed, fully automatic calibration scheme is used to
ensure that the frequency and amplitude characteristic of the
VCO are maintained over temperature, supply voltage, and
process variations.
The calibration is automatically performed when the
CMD_PHY_RX or CMD_PHY_TX command is issued.
The calibration duration is 142 µs, and if required, the
CALIBRATION_STATUS register (Address 0x339) can be
polled to indicate the completion of the VCO self-calibration.
After the VCO is calibrated, the frequency synthesizer settles to
within ±5 ppm of the target frequency in 56 µs.
Figure 107. RF Frequency Synthesizer Architecture
Synthesizer Bandwidth
The synthesizer loop filter is fully integrated on chip and has a
programmable bandwidth. The communications processor
automatically sets the bandwidth of the synthesizer when the
device enters PHY_TX or PHY_RX state. On entering the
PHY_TX state, the communications processor chooses the
bandwidth based on the programmed modulation scheme
(2FSK, GFSK, or OOK) and the data rate. This ensures optimum
modulation quality for each data rate. On entering the PHY_RX
state, the communications processor sets a narrow bandwidth to
ensure best receiver rejection. In all, there are eight bandwidth
configurations. Each synthesizer bandwidth setting is described
in Table 30.
Table 30. Automatic Synthesizer Bandwidth Selections
Description
Data Rate
(kbps)
Closed Loop
Synthesizer
Bandwidth (kHz)
Rx 2FSK/GFSK/MSK/GMSK
All
92
Tx 2FSK/GFSK/MSK/GMSK
1 to 49.5
130
Tx 2FSK/GFSK/MSK/GMSK
49.6 to 99.1
174
Tx 2FSK/GFSK/MSK/GMSK
99.2 to 129.5
174
Tx 2FSK/GFSK/MSK/GMSK
129.6 to 179.1
226
Tx 2FSK/GFSK/MSK/GMSK
179.2 to 239.9
305
Tx 2FSK/GFSK/MSK/GMSK
240 to 300
382
Tx OOK
All
185
Synthesizer Settling
After the VCO calibration, a 56 μs delay is allowed for synthesizer
settling. This delay is fixed at 56 μs by default and ensures that
the synthesizer has fully settled when using any of the default
synthesizer bandwidths.
However, in some cases, it may be necessary to use a custom
synthesizer settling delay. To use a custom delay, set the
CUSTOM_TRX_SYNTH_LOCK_TIME EN bit to 1 in the
MODE_CONTROL register (Address 0x11A). The synthesizer
settling delays for the PHY_RX and PHY_TX state transitions
can be set independently in RX_SYNTH_LOCK_TIME register
(Address 0x13E) and the TX_SYNTH_LOCK_TIME register
(Address 0x13F). The settling time can be set in the range 2 μs
to 512 μs in steps of 2 μs.
Bypassing VCO Calibration
It is possible to bypass the VCO calibration for ultrafast frequency
hopping in transmit or receive. The calibration data for each RF
channel should be stored in the host processor memory. The
calibration data comprises two values: the VCO band select
value and the VCO amplitude level.
Read and Store Calibration Data
1. Go to the PHY_TX or PHY_RX state without bypassing
the VCO calibration.
2. Read the following MCR registers and store the calibrated
data in memory on the host processor:
a. VCO_BAND_READBACK (Address 0x3DA)
b. VCO_AMPL_READBACK (Address 0x3DB)
F_DEVIATION
RF
FREQ
LOOP
FILTER
VCO
26MHz
REF
TX
DATA
FRAC-N
INTEGER-N
N DIVIDER
VCO
CALIBRATION
Σ-Δ DIVIDER
GAUSSIAN
FILTER
PFD
CHARGE
PUMP
÷2 OR
÷4
÷2



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com