công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

EVAL-ADF7023DB2Z bảng dữ liệu(PDF) 74 Page - Analog Devices

tên linh kiện EVAL-ADF7023DB2Z
Giải thích chi tiết về linh kiện  High Performance, Low Power, ISM Band FSK/GFSK/OOK/MSK/GMSK Transceiver IC
PDF  112 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  AD [Analog Devices]
Trang chủ  http://www.analog.com
Logo AD - Analog Devices

EVAL-ADF7023DB2Z bảng dữ liệu(HTML) 74 Page - Analog Devices

Back Button EVAL-ADF7023DB2Z Datasheet HTML 70Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 71Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 72Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 73Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 74Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 75Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 76Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 77Page - Analog Devices EVAL-ADF7023DB2Z Datasheet HTML 78Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 74 / 112 page
background image
ADF7023
Data Sheet
Rev. C | Page 74 of 112
Bypassing VCO Calibration on CMD_PHY_TX or
CMD_PHY_RX
1. Ensure that the BBRAM is configured.
2. Set VCO_OVRW_EN (Address 0x3CD) = 0x3.
3. Set VCO_CAL_CFG (Address 0x3D0) = 0x0F.
4. Set VCO_BAND_OVRW_VAL (Address 0x3CB) = stored
VCO_BAND_READBACK (Address 0x3DA) for that
channel.
5. Set VCO_AMPL_OVRW_VAL (Address 0x3CC)= stored
VCO_AMPL_READBACK (Address 0x3DB) for that
channel.
6. Set SYNTH_CAL_EN = 0 (in the CALIBRATION_
CONTROL register, Address 0x338).
7. Set SYNTH_CAL_EN = 1 (in the CALIBRATION_
CONTROL register, Address 0x338).
8. Issue CMD_PHY_TX or CMD_PHY_RX to go to the
PHY_TX or PHY_RX state without the VCO calibration.
CRYSTAL OSCILLATOR
A 26 MHz crystal oscillator operating in parallel mode must be
connected between the XOSC26P and XOSC26N pins. Two
parallel loading capacitors are required for oscillation at the
correct frequency. Their values are dependent upon the crystal
specification. They should be chosen to ensure that the shunt
value of capacitance added to the PCB track capacitance and the
input pin capacitance of the ADF7023 equals the specified load
capacitance of the crystal, usually 10 pF to 20 pF. Track capacitance
values vary from 2 pF to 5 pF, depending on board layout. The
total load capacitance is described by
CLOAD =
PCB
C
PIN
C
2
C
1
C
+
+
+
2
1
1
1
where:
CLOAD is the total load capacitance.
C1 and C2 are the external crystal load capacitors.
CPIN is the ADF7023 input capacitance of the XOSC26P and
XOSC26N pins and is equal to 2.1pF.
CPCB is the PCB track capacitance.
When possible, choose capacitors that have a very low
temperature coefficient to ensure stable frequency operation
over all conditions.
The crystal frequency error can be corrected by means of an
integrated digital tuning varactor. For a typical crystal load
capacitance of 10 pF, a tuning range of +15 ppm to −11.25 ppm
is available via programming of a 3-bit DAC, according to Table 31.
The 3-bit value should be written to XOSC_CAP_DAC in the
OSC_CONFIG register (Address 0x3D2).
Alternatively, any error in the RF frequency due to crystal error
can be adjusted for by offsetting the RF channel frequency using
the RF channel frequency setting in BBRAM memory.
Table 31. Crystal Frequency Pulling Programming
XOSC_CAP_DAC
Pulling (ppm)
000
+15
001
+11.25
010
+7.5
011
+3.75
100
0
101
−3.75
110
−7.5
111
−11.25
MODULATION
The ADF7023 supports binary frequency shift keying (2FSK),
minimum shift keying (MSK), binary level Gaussian filtered
2FSK (GFSK), Gaussian filtered MSK (GMSK), and on-off
keying (OOK). The desired transmit and receive modulation
formats are set in the RADIO_CFG_9 register (Address 0x115).
When using 2FSK/GFSK/MSK/GMSK modulation, the frequency
deviation can be set using the FREQ_DEVIATION[11:0]
parameter in the RADIO_CFG_1 register (Address 0x10D) and
RADIO_CFG_1 register (Address 0x10E). The data rate can be
set in the 1 kbps to 300 kbps range using the DATA_RATE[11:0]
parameter in the RADIO_CFG_0 register (Address 0x10C) and
RADIO_CFG_1 register (Address 0x10D). For GFSK/GMSK
modulation, the Gaussian filter uses a fixed bandwidth time
(BT) product of 0.5.
When using OOK modulation, it is recommended to enable
Manchester encoding (MANCHESTER_ENC = 1, Address
0x11C). The data rate can be set in the 2.4 kbps to 19.2 kbps
range (4.8 kcps to 38.4 kcps Manchester encoded) using the
DATA_RATE[11:0] parameter in the RADIO_CFG_0 register
(Address 0x10C) and RADIO_CFG_1 register (Address 0x10D).
RF OUTPUT STAGE
Power Amplifier (PA)
The ADF7023 PA can be configured for single-ended or
differential output operation using the PA_SINGLE_DIFF_SEL
bit in the RADIO_CFG_8 register (Address 0x114). The PA
level is set by the PA_LEVEL bit in the RADIO_CFG_8 register
and has a range of 0 to 15. For finer control of the output power
level, the PA_LEVEL_MCR register (Address 0x307) can be
used. It offers more resolution with a setting range of 0 to 63.
The relationship between the PA_LEVEL and PA_LEVEL_MCR
settings is given by
PA_LEVEL_MCR = 4 × PA_LEVEL + 3
The single-ended configuration can deliver 13.5 dBm output
power. The differential PA can deliver 10 dBm output power
and allows a straightforward interface to dipole antennae. The
two PA configurations offer a Tx antenna diversity capability.
Note that the two PAs cannot be enabled at the same time.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com