30 / 121 page ![]() ________________________________________________________________________________________________________________________________________________________________ MAX17823B 12-Channel High-Voltage Data Acquisition System www.maximintegrated.com Maxim Integrated | 30 Figure 13. Double-Buffer Mode Register Read Measurement Alerts After the measurement cycle, the ALU compares the enabled measurements to the various configured thresholds as shown in Table 10 and sets the alert bits before the ALU data is transferred to the data registers. In oversampling mode, the alert status is updated after the last oversample. The alerts are updated whether or not the data is moved from the ALU registers to the data registers and are only updated for those measurements enabled in the MEASUREEN register. Table 10. Measurement Alerts Description Condition or Result Alert Bit Location Cell over-voltage (OV) VCn - VCn-1 > VVOVTHSET ALRTOV, ALRTOVn STATUS, ALRTOVCELL Cell under-voltage (UV) VCn - VCn-1 < VUVTHSET ALRTUV, ALRTUVn STATUS, ALRTUVCELL Cell Mismatch VMAX - VMIN > VMSMTCH ALRTMSMTCH STATUS Cell with minimum voltage n where VCELLn = VMIN None MINMAXCELL Cell with maximum voltage n where VCELLn = VMAX None MINMAXCELL Total of all cell voltages Σ VCELLn for n = 1 to 12 None TOTAL AUXINx over-voltage (under-temperature) VAUXINx > VAINUT ALTRTCOLD, ALRTOVAINx STATUS, ALRTOVCELL AUXINx under-voltage (over-temperature) VAUXINx < VAINOT ALRTHOT, ALRTUVAINx STATUS, ALRTUVCELL Voltage Alerts Use the ALRTOVEN and ALRTUVEN registers to enable voltage alerts for the cell and auxiliary inputs. If a cell voltage alert is enabled, the cell input voltage is compared against the programmable over-voltage and under-voltage thresholds after every acquisition as shown in Figure 14. Separate thresholds for setting the alert and for clearing the alert provide hysteresis. Configure the set thresholds for cell under-voltage (VUVTHSET) and over-voltage (VOVTHSET) using the OVTHSET and UVTHSET registers. Configure the clear thresholds for cell under-voltage (VUVTHCLR) and cell over-voltage (VOVTHCLR) using the OVTHCLR and UVTHCLR registers. Alert flags in the ALRTOVCELL register are set, if enabled, when the acquired cell voltage is over VOVTHSET. Alerts in MAX178xx Comm. Idle; DBLBUF=1 Read SCANDONE Set? No Yes Write SCANDONE=0 Write SCAN=1 to start scan DATARDY=0? Yes No Process existing user register data first MAX178xx Comm. Idle DATARDY=1? No Fault Condition; Data should be available Yes Read all user measurement registers Write DATARDY=0 DATARDY=0? No Yes Fault Condition; New data should not be available |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |