15 / 52 page ![]() PRELIMINARY DATA SHEET MAS 3506D Micronas 15 3.3. I2C-Data Register (Subaddresses 68hex and 69hex) and the MAS 3506D DSP-Command Syntax The I2C data register is used to communicate with the internal firmware of the MAS 3506D. It is readable (subaddress “data_read”) and writable (subaddress “data_write”) and also has a length of 16 bits. The data transfer is done with the most significant bit (m) first. A special command language is used that allows the controller to access the DSP-registers and RAM-cells and thus monitor internal states, set the parameters for the DSP-firmware, control the hardware, and even pro- vide a download of alternative software modules. The DSP-commands consist of a “Code” which is sent to to I2C-data register together with additional parameters. Table 3–5 gives an overview over the different com- mands which the DSP-core may receive. The “Code” is always the first data nibble transmitted after the “data_write” byte. The control interface is also used for low-bit-rate data transmission, i.e. MPEG-embedded ancillary data and the WorldSpace Service Control Header. These data are available in a specified memory area of the MAS 3506D after successful decoding. The synchroni- zation between controller and the MAS 3506D will be done by observing the BC-FRAME-SYNC and MPEG- FRAME-SYNC signals in register c8hex or at the corre- sponding pins. Table 3–4: Data register bit assignment 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 ml ... SDW data_write WA A A A Code,... ...,... Table 3–5: Basic controller command codes for the MAS 3506D Code (hex) Command Function 0 Run Start execution of an internal program. Run with start address 0hex means freeze the operating system 1 Run Config Start execution of an internal program and switch config RAM to P-RAM 5 Select SC Select the Service Component 6 Read Ancillary Data Read MPEG ancillary data 8 Read SCH-Data Read Service Control Header 9 Write Register An internal register of the MAS 3506D can directly be written to by the con- troller a, b Write Memory A block of the DSP memory can be written to by the controller. (This feature may be used to download alternate programs.) d Read Register The controller can read an internal register of the MAS 3506D e, f Read Memory A block of the DSP memory can be read by the controller |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |