| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
D10AFPGQ bảng dữ liệu(PDF) 3 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
D10AFPGQ bảng dữ liệu(HTML) 3 Page - Banner Engineering Corp. |
|
3 / 6 page ![]() Specifications Sensing Beam Visible red, 660 nm or Visible green, 525 nm , depending on model Supply Voltage 10 to 30 V dc (10% max. ripple) at less than 25 mA, exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN) Output Rating 100 mA per output with short circuit protection OFF-state leakage current: < 10 μA sourcing; 200 μA sinking ON-state saturation voltage: NPN: 1.6 V at 100 mA PNP: 2.0 V at 100 mA Output Protection Protected against output short-circuit and false pulse on power up NOTE: Maximum 100 ms delay on power up; outputs do not conduct during this time Output Response Time Standard models (with crosstalk avoidance circuitry): 500 microseconds High-speed models: 200 microseconds Repeatability Standard models: 95 microseconds High-speed models: 50 microseconds Adjustments 12-turn Sensitivity potentiometer with relative position indicator; LO/DO Selection switch; 0 or 40 ms off delay switch NOTE: Use proper ESD techniques while making adjustments under cover. Indicators Two LEDs: Green and Amber Green ON steady: Power ON Amber flashing: Light Sensed Signal strength indicator (Banner’s AID™ Alignment Indicating Device—the faster the flash, the more light is received) Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Environmental Rating IEC IP50, NEMA 1 Connections 2 m or 9 m (6.5 ft or 30 ft) attached cable, or 4-pin Pico-style quick- disconnect fitting; cables for QD models are purchased separately Operating Conditions Operating Temperature: −10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature: −20 °C to +85 °C (−4 °F to +185 °F) 90% at +55 °C maximum relative humidity (non-condensing) Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Certifications D10—Discrete Output P/N 118431 Rev. B www.bannerengineering.com - Tel: +1-763-544-3164 3 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |