| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
45SD bảng dữ liệu(PDF) 5 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
45SD bảng dữ liệu(HTML) 5 Page - Banner Engineering Corp. |
|
5 / 6 page ![]() 61 Configuration Register: This is a single byte, 8 flags. bit 0 - 2 not used. bit 3 Disable re-transmission of COS messages R/W . When this bit is set ALL event driven messages are sent only once per event. Unacknowledged messages are not resent. bit 4 - 7 not used. This attribute is stored in non volatile memory. ACTIONS Action Description Requested Data Requested Data Type Response Data Response Data Type 0 No Operation None None 1 Change Address New Address Unsigned 8 None Device ID* Unsigned 8 Partner ID* Unsigned 16 Serial No.* Unsigned 32 2 Self Test None None 6 Clear All Errors None None 8 Enroll Logical Device None Partner ID Unsigned 16 Serial No. Unsigned 32 51 Force Input Input State Unsigned 8 None 52 Remove Forced Input None None 53 Read Primitive Tag Attribute ID Attribute ID Unsigned 8 Primitive tage Unsigned 32 * These parameters are optional 0 NO-OP: This is used primarily during “Autobaud” and to solicit a response from another node to verify bus integrity. No action is performed by our device. 1 Change Address: There are two methods to change the address. • If the message contains one or two data bytes the address is changed to the address defined by the first byte. The second byte is ignored. • If the message contains eight data bytes, then bytes 3 and 4 are checked against the Vendor ID. Bytes 5-8 are checked against the Serial Number. If the Vendor ID and Serial Number are correct, then byte 1 is used to determine the new address. If either is not correct the message is ignored. 2 Initiate Self Test: This action initiates a self test sequence internal to the node. This action is acknowledged prior to the start of the self test. An Event ID 0 is then transmitted only if internal errors are found. 6 Reset Errors: This action clears the error flags in both bytes of attribute #9, Bus Diagnostic Register. 8 Enroll: Enroll returns a 6 byte message. The first four data bytes are the Serial Number and the remaining two bytes are the Vendor Identification Number. The firmware waits for a random delay, up to 10 ms, before responding to this action. This delay makes it possible to detect multiple devices with the same logical address. 51 Force Input/Output Variable State: This forces the logical state of the Input, Attribute #18. The data contains a Boolean single byte: 00 or 01. 52 Remove Force Input/Output Variable State: This function removes the forced state, and restores normal operation. 53 Read Primitive Tag: This action is called with one byte of input data - the attribute number. This action responds with the following 3 bytes of data: Attribute # (unsigned 8), Primitive Tag (unsigned 16). 5 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |