công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

T18-2VPLPC-Q8 bảng dữ liệu(PDF) 3 Page - Banner Engineering Corp.

tên linh kiện T18-2VPLPC-Q8
Giải thích chi tiết về linh kiện  Epoxy Encapsulated Right-Angle Sensor
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  BANNER [Banner Engineering Corp.]
Trang chủ  https://www.bannerengineering.com/us/en.html
Logo BANNER - Banner Engineering Corp.

T18-2VPLPC-Q8 bảng dữ liệu(HTML) 3 Page - Banner Engineering Corp.

  T18-2VPLPC-Q8 Datasheet HTML 1Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 2Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 3Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 4Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 5Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 6Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 7Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 8Page - Banner Engineering Corp. T18-2VPLPC-Q8 Datasheet HTML 9Page - Banner Engineering Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 10 page
background image
Specifications
Supply Voltage
10 V dc to 30 V dc for ambient temperature ≤ 55 °C
10 V dc to 24 V dc for ambient temperature > 55 °C
Supply Current (Exclusive of Load Current)
All models except FF IR: < 16 mA
FF IR models: < 25 mA
Output Protection Circuitry
Protected against false pulse on power-up and continuous short
circuit of outputs. Short circuit protection at elevated temperature
may require a power cycle to reset.
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Rating
≤ 50 mA total current for ambient temperatures > 55 °C
≤ 100 mA total current through both outputs ≤ 55 °C
OFF-State Leakage Current: < 50 µA at 30 V dc
ON-State Saturation Voltage: < 1.5 V at 10 mA; < 3.0 V at 100 mA
Output Configuration
Complementary PNP or NPN by model number
Emitter LED
Visible Red on most models
Infrared 850 nm on select fixed-field models to provide higher
excess gain on blue and green targets
Output Response Time
Response is independent of signal strength
Opposed models: 1.5 milliseconds ON, 1 millisecond OFF
Polarized Retro, and Diffuse models: 1.5 milliseconds ON, 0.75
milliseconds OFF
Fixed Field models: 2 milliseconds ON, 2 milliseconds OFF
Delay on Power-up: 100 milliseconds; outputs do not conduct
during this time
Repeatability
Repeatability is independent of signal strength
Opposed models: 300 microseconds
Retro, Polarized Retro, and Diffuse models: 100 microseconds
Fixed Field models: 200 microseconds
Adjustments
Diffuse (DL, DS), Emitter (ES), Receiver (RS), Polarized
Retroreflective (LPC) models: Single turn sensitivity (gain)
adjustment potentiometer
Emitter Beam Inhibit (EJ) models: Tie black wire to 10 to 30 V dc for
beam inhibit
Construction
Housing, M12 QD, and cover: Black or Yellow PBT polyester
Indicator light pipes: Translucent white PMMA (acrylic)
Indicator cover and gain pot driver: PBT polyester
Front window: PMMA
Indicators
Two LEDs (1 green, 1 amber)
Green Solid: Indicates power applied and sensor ready
Green flashing: Indicates marginal sensing signal
Amber solid: Indicates Pin-4 (black wire) conducting
Vibration and Mechanical Shock
All models meet Mil. Std. 202G requirements. Method 201A
(Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06 in
acceleration 10G). Method 213B conditions H&I (Shock: 75G with
unit operating; 100G for non-operation)
Operating Conditions
–40 °C to +70 °C (–40 °F to +158 °F)
95% at +50 °C maximum relative humidity (non-condensing)
Environmental Rating
IEC IP67 per IEC60529
IEC IP68 per IEC60529
DIN IP69K
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
Chemical compatibility certified
ECOLAB is a registered trademark of Ecolab USA Inc. All rights
reserved.
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in
accordance with local and national
electrical codes and regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com.
Supply Wiring
(AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
T18-2 Epoxy Encapsulated Right-Angle Sensor
P/N 201875 Rev. C
www.bannerengineering.com - Tel: +1-763-544-3164
3



Html Pages

1 2 3 4 5 6 7 8 9 10


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com