| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
M29DW128F bảng dữ liệu(PDF) 40 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29DW128F bảng dữ liệu(HTML) 40 Page - STMicroelectronics |
|
40 / 93 page ![]() 6 Command Interface M29DW128F 40/93 Once the Password Protection mode is activated the device will permanently remain in this mode. 6.3.9 Verify Password Protection Mode command The Verify Password Protection Mode command reads the status of the Password Protection Mode Lock Bit. If it is ‘1’, the device is in Password Protection mode. 6.3.10 Set Standard Protection Mode command The Set Standard Protection Mode command puts the device in Standard Protection mode by programming the Standard Protection Mode Lock bit to ‘1’. Six cycles are required to issue the Standard Protection Mode command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the program command. 3. The fourth and fifth cycles select the address (see Table 17: Protection Command Addresses). 4. The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the Standard Protection Mode has been successfully activated. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. There must be a 100µs delay between the fourth and fifth cycles. Once the Standard Protection mode is activated the device will permanently remain in this mode. 6.3.11 Verify Standard Protection Mode command The Verify Standard Protection Mode command reads the status of the Standard Protection Mode Lock Bit. If it is ‘1’, the device is in Standard Protection mode. 6.3.12 Set Non-Volatile Modify Protection Bit command A block or group of blocks can be protected from program or erase by issuing a Set Non-Volatile Modify Protection Bit command along with the block address. This command sets the Non- Volatile Modify Protection bit to ‘1’ for a given block or group of blocks. Six cycles are required to issue the command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the program command. 3. The fourth and fifth cycles select the address (see Table 17: Protection Command Addresses). 4. The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the Non- Volatile Modify Protection bit has been successfully programmed. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. There must be a 100µs delay between the fourth and fifth cycles. The Non-Volatile Modify Protection bits are erased simultaneously by issuing a Clear Non- Volatile Modify Protection Bits command except if the Lock-Down bit is set to ‘1’. The Non-Volatile Modify Protection bits can be set a maximum of 100 times. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |