| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAS6512 bảng dữ liệu(PDF) 12 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6512 bảng dữ liệu(HTML) 12 Page - Micro Analog systems |
|
12 / 32 page ![]() DA6512.003 2 December, 2016 12 (32) MEASUREMENT CONTROL REGISTER (E2/62HEX) This register is used to configure and initiate a measurement. See table 3 below. A new conversion is started simply by writing 8-bit configuration data having SCO=1 to the measurement control register (E2/62HEX). Table 3. Measurement control register (E2/62HEX) description Bit Number Bit Name Description Value Function 7-5 OSRS Over Sampling Ratio (OSR) Selection 000 001 010 011 OSR = 256 OSR = 512 OSR = 1024 OSR = 2048 4 TEMPREGEN Temperature Mode Regulator Enable 0 1 Voltage regulator disabled Voltage regulator enabled 3 SCO Start Conversion 0 1 No conversion Start conversion 2-1 SEL Capacitive/ VDD Monitoring / Temperature Selection 00 01 10 11 External capacitive sensor VDD level monitoring Internal temperature sensor - 0 XRC Front end function selector 0 1 Ratio converter Difference converter The OSRS over sampling ratio selection bits choose between four different OSR values. High OSR value corresponds to high resolution but also longer conversion time. See Electrical characteristics for further details. The TEMPREGEN bit enables/disables the internal temperature mode voltage regulator. The regulator need to be enabled (TEMPREGEN=1) only in temperature mode and it should be disabled (TEMPREGEN=0) in capacitance and VDD monitoring modes. When enabled the regulator is turned on during conversions and automatically turned off after each conversion to save power. Note also that if in Test register FOSC=1 and if TEMPREGEN=1 the regulator is forced on all the time even when measurement is not running. The SCO Start conversion bit needs to be set 1 for every new measurement. It is automatically reset to 0 after each measurement. The SEL sensor selection bits control the front-end multiplexer. It connects either the external capacitive sensor (SEL=00), VDD level monitoring voltage (SEL=01) or the internal temperature sensor (SEL=10) to the -converter. The XRC bit selects between two external capacitive sensor measurement modes. The XRC bit selection does not have any effect on temperature or VDD level monitoring measurements. In Ratio converter mode the output will be proportional to capacitance ratio (CS-CR)/CS. In Difference converter mode the output will be proportional to capacitance difference (CS-CR). |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |