| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TPS1663 bảng dữ liệu(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TPS1663 bảng dữ liệu(HTML) 16 Page - Texas Instruments |
|
16 / 30 page ![]() IMON VIN VOUT IIN 16 TPS1663 SLVSET9A – SEPTEMBER 2018 – REVISED OCTOBER 2018 www.ti.com Product Folder Links: TPS1663 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated Feature Description (continued) Figure 8. IMON Response During a Load Step 8.3.8 FAULT Response (FLT) The FLT open-drain output asserts (active low) under the faults events such as undervoltage, overvoltage, over load, power limiting, reverse current and thermal shutdown conditions. The device is designed to eliminate false reporting by using an internal "de-glitch" circuit for fault conditions without the need for an external circuitry. FLT can be left open or connected to GND when not used. 8.3.9 IN, P_IN, OUT and GND Pins Connect a minimum of 0.1 uF capacitor across IN and GND. Connect P_IN and IN together. Do not leave any of the IN and OUT pins un-connected. 8.3.10 Thermal Shutdown The device has a built-in overtemperature shutdown circuitry designed to protect the internal FET, if the junction temperature exceeds T(TSD). After the thermal shutdown event, depending upon the mode of fault response, the device either latches off or commences an auto-retry cycle t(TSD_retry) after TJ < [T(TSD) – 11°C]. During the thermal shutdown, the fault pin FLT pulls low to indicate a fault condition. 8.3.11 Low Current Shutdown Control (SHDN) The internal and the external FET and hence the load current can be switched off by pulling the SHDN pin below 0.8 V threshold with a micro-controller GPIO pin or can be controlled remotely with an opto-isolator device. The device quiescent current reduces to 22 μA (typical) in shutdown state. To assert SHDN low, the pull down must sink at least 10 µA at 400 mV. To enable the device, SHDN must be pulled up to atleast 2 V. Once the device is enabled, the internal FET turns on with dVdT mode. 8.4 Device Functional Modes The TPS1663x devices respond differently to overload with MODE pin configurations. The operational differences are explained in Table 1. Table 1. Device Operational Differences Under Different MODE Configurations MODE Pin Configuration Overload Protection Operation Open Active Current limiting at 1x for a maximum duration of tCL_PLIM(dly). There after Latches OFF. Latch reset by toggling SHDN low to high or power cycling IN Shorted to GND Active Current limiting at 1x for a maximum duration of tCL_PLIM(dly). There after auto-retries after a delay of t(TSD_retry). |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |