| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
W2RG012RN bảng dữ liệu(PDF) 9 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
W2RG012RN bảng dữ liệu(HTML) 9 Page - Omron Electronics LLC |
|
9 / 21 page ![]() LED Control IC W2RG012RN 9 ■ Command System Device Designation If the device ID and device address match IC settings, received data are retrieved. Device ID is fixed as “010”. The same command can be trans- mitted to all devices by designating “1111” as device address. The relationship between device address and device address terminal is shown in the table below. Register Designation Word Length The data unit of gradation data is designated. Register Address (Designation of lighting position) The address of gradation register is designated. The upper limit of address that can be designated, and the number of gradation that can be trans- ferred continuously, vary according to division mode setting and word length designation. Register address (Special address) All gradation registers can be designated collectively by designating 0x7F (127). The power saving register can be designated by designating 0x78 (120) Gradation Data Gradation Designation Gradation data are designated using 8 bits (256 gradations), 7 bits (128 gradations), or 4 bits (16 gradations). Power-saving Mode When the power-saving data register is designated by register address-bits, the lowest 4 bits are treated as power-saving data. Communication mode Device selection data dvc_dat (7:0) 76543210 Device ID Device Address RW Standard 0 1 0 ADR1(1:0) ADR0(1:0) 0 SP-D7 --- Communication mode Register Selection data reg_dat (7:0) 76543210 Standard Word Length Register Address SP-D7 - - - Word length designation Word length 0 8bit 1 4bit Communication mode Gradation data light_dat(7:0) 76543210 Standard (8-bit) Gradation Data Standard (4-bit) Gradation Data N Gradation Data N+1 SP-D7 Gradation Data - - - Communication mode Gradation data light_dat(7:0) 7654 3 2 1 0 Standard 0000 Power-saving data (current control) Power-saving data (duty ratio control) SP-D7 - - - 0 0 0 Power-saving Data Output current or output duty ratio 00 100% 01 75% 10 50% 11 25% |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |