| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LTC3871 bảng dữ liệu(PDF) 16 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC3871 bảng dữ liệu(HTML) 16 Page - Linear Technology |
|
16 / 24 page ![]() LTC7106 16 Rev A For more information www.analog.com Figure 7. MFR_RAIL_ADDRESS Data Byte PMBus COMMAND DETAILS 7106 F07 B7 B0 7-BIT ADDRESS CLEAR B7 TO ENABLE RAIL ADDRESS MFR_RESET This command provides a means by which the user can perform a reset of the LTC7106. All latched faults (ALERT and status register) and register contents will be reset to a power-on condition by this command. VOUT will remain in regulation but may change due to the reset of the margin registers. This write-only command accepts zero, one, or two data bytes but ignores them. MFR_RAIL_ADDRESS The MFR_RAIL_ADDRESS command allows all devices to share a common address, such as all devices attached to a single power supply rail. The desired 7-bit address value is written to the 7 bits of the data byte. TheMSB(bitB7)mustbesetlowtoenablecommunication using the MFR_RAIL_ADDRESS address. Setting this bit disables this address. The default for this register is 0x80. OPERATION The OPERATION command is used to turn the unit on/off and for margining the output voltage. The ON bit is automatically reset to ON after a master shutdown (EN), power cycle, or MFR_RESET command. The MARGIN_LOW/HIGH bits command the IOUT refer- ence to the offset value stored in either the MFR_IOUT_ MARGIN_HIGH or MFR_IOUT_MARGIN_LOW. This command has one data byte. It will accept one or two but ignores the second byte. Table 6. Supported OPERATION Command Register Values ACTION VALUE Turn Off Immediately 0x00 Turn On 0x80 Margin Low 0x98 Margin High 0xA8 PMBus_REVISION ThePMBUS_REVISIONcommandindicatestherevisionof the PMBus to which the device is compliant. The LTC7106 is PMBus Version 1.2 compliant in both Part I and Part II. This read-only command has one data byte and will return 0x22. MFR_SPECIAL_ID The 16-bit word representing a unique identification for LTpowerPlay. This read-only command has 2 data bytes and is set to 0x8080. The user should only perform command writes to this address. If a read is performed from this address and the rail devices do not respond with EXACTLY the same value, the LTC7106 will detect bus contention and abort its read command with no CML or ALERTB set. This command accepts one or two data bytes but the second is ignored. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |