21 / 25 page ![]() AD7298 Rev. B | Page 20 of 24 Full Power-Down Mode In this mode, all internal circuitry on the AD7298 is powered down and no information is retained in the control register or any other internal register. If the averaging feature for the tempera- ture sensor is enabled in the control register (TSENSEAVG), the averaging is reset once the device enters power-down mode. The AD7298 is placed into full power-down mode by bringing the logic level on the PD/RST pin low for greater than 100 ns. When placing the AD7298 in full power-down mode, the ADC inputs must return to 0 V. The PD/RST pin is asynchronous to the clock, thus it can be triggered at any time. The part can be powered up for normal operation by bringing the PD/RST pin logic level back to a high logic state. The full power-down feature can be used to reduce the average power consumed by the AD7298 when operating at lower throughput rates. The user should ensure that tPOWER_UP has elapsed prior to programming the control register and initiating a valid conversion. POWERING UP THE AD7298 The AD7298 contains a power-on reset circuit, which sets the control register to its default setting of all zeros, thus the internal reference is enabled and the device is configured for the normal mode of operation. On power-up, the internal reference is by default enabled, which takes up 6 ms (maximum) to power-up. If an external reference is being used, the user does not need to wait for the internal reference to power-up fully. The AD7298 digital interface is fully functional after 500 μs from initial power-up. Therefore, the user can write to the control register after 500 μs to switch to external reference mode. The AD7298 is then immediately ready to convert once the external reference is available on the VREF pin. When supplies are first applied to the AD7298, the user must wait the specified 500 μs before programming the control register to select the desired channels for conversion. RESET The AD7298 includes a reset feature that can be used to reset the device and the contents of all internal registers, including the control register, to their default state. To activate the reset operation, the PD/RST pin should be brought low for no longer than 100 ns. It is asynchronous with the clock, thus it can be triggered at any time. If the PD/RST pin is held low for greater than 100 ns, the part enters full power- down mode. It is imperative that the PD/RST pin be held at a stable logic level at all times to ensure normal operation. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |