| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PC33996EK/R2 bảng dữ liệu(PDF) 14 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
PC33996EK/R2 bảng dữ liệu(HTML) 14 Page - Motorola, Inc |
|
14 / 16 page ![]() 33996 MOTOROLA ANALOG INTEGRATED CIRCUIT DEVICE DATA 14 source voltage of the specific MOSFET output to an internally generated reference. Each output has one dedicated comparator for this purpose. Each 33996 output has an internal 50 µA pull-down current source. The pull-down current is disabled on power-up and must be enabled for Open Load Detect to function. Once enabled, the 33996 will only shut down the pull-down current in Sleep mode or when disabled via SPI. During output switching, especially with capacitive loads, a false Output OFF Open Load Fault may be triggered. To prevent this false fault from being reported, an internal fault filter of 100 µs to 450 µs is incorporated. The duration for which a false fault may be reported is a function of the load impedance, RDS(ON), COUT of the MOSFET, as well as the supply voltage, VPWR. The rising edge of CS triggers the built-in fault delay timer. The timer must time out before the fault comparator is enabled to detect a faulted threshold. Once the condition causing the Open Load Fault is removed, the device resumes normal operation. The Open Load Fault, however, will be latched in the output SO Response register for the MCU to read. Shorted Load Fault A shorted load (overcurrent) fault can be caused by any output being shorted directly to supply, or by an output experiencing a current greater than the current limit. Three safety circuits progressively in operation during load short conditions afford system protection: 1. The device’s output current is monitored in an analog fashion using a SENSEFET approach and is current limited. 2. With the output in current limit, the drain-to-source voltage will increase. By setting the SFPD bit to 0, the output will shut down on VDS > 2.7 V typical after 450 µs. 3. The device’s output thermal limit is sensed and when attained causes only the specific faulted output to shutdown. The device remains OFF until cooled. The device then operates as programmed by the shutdown/ retry bit. The cycle continues until the fault is removed or the command bit instructs the output OFF. All three protection schemes set the Fault Status bit (bit 23 in the SO Response register) to logic [1]. Undervoltage Shutdown An undervoltage SOPWR condition results in the global shutdown of all outputs and reset of all control registers. The undervoltage threshold is between 2.0 V and 3.0 V. An undervoltage condition at the VPWR pin results in an output shutdown and reset. The undervoltage threshold is between 3.2 V and 3.5 V. When VPWR is between 5.0 V and 3.5 V, the output may operate per the command word and the status is reported on SO pin, though this is not guaranteed. Output Voltage Clamp Each output of the 33996 incorporates an internal voltage clamp to provide fast turn-OFF and transient protection of each output. Each clamp independently limits the drain-to-source voltage to 50 V. The total energy clamped (EJ) can be calculated by multiplying the current area under the current curve (IA) times the clamp voltage (VCL) (see Figure 7). Characterization of the output clamps, using a single pulse non-repetitive method at 0.3 A, indicates the maximum energy to be 50 mJ at 150 °C junction temperature per output. Figure 7. Output Voltage Clamping Reverse Battery Protection The 33996 device requires external reverse battery protection on the VPWR pin. All outputs consist of a power MOSFET with an integral substrate diode. During reverse battery condition, current will flow through the load via the substrate diode. Under this circumstance relays may energize and lamps will turn on. If load reverse battery protection is desired, a diode must be placed in series with the load. Overtemperature Fault Overtemperature detect circuits are specifically incorporated for each individual output. The shutdown following an overtemperature condition depends on the control bit set in the Global Shutdown/Retry Control register. Each independent output shuts down at 155°C to 180°C. When an output shuts down due to an Overtemperature Fault, no other outputs are affected. The MCU recognizes the fault by a logic [1] in the Fault Status bit (bit 23 in the SO Response register). After the 33996 has cooled below the switch point temperature and 10°C hysteresis, the output will function as defined by the shutdown/ retry bit 17 in the Global Shutdown/Retry Control register. Current Area (IA ) Clamp Energy (E J = IA x VCL ) Drain Voltage Time Drain-to-Source C lamp Voltage (VCL = 45 V) Drain Current (I D = 0.3 A) GND Drain-to-Source ON Voltage (VDS(O N)) 50 V) Drain-to-Source Clamp Voltage (VCL = 50 V) Drain-to-Source ON Voltage (VDS(ON)) Drain Voltage Clamp Energy (EJ = IA x VCL) GND Time Drain Current (ID = 0.3 A) Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |