| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
P3602ACMC bảng dữ liệu(PDF) 131 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
P3602ACMC bảng dữ liệu(HTML) 131 Page - Teccor Electronics |
|
131 / 212 page ![]() GR 1089–Core © 2002 Teccor Electronics 4 - 7 http://www.teccor.com SIDACtor® Data Book and Design Guide +1 972-580-7777 First Level AC Power Fault Criteria Table 4.6 presents test conditions for the First Level AC Power Fault Test. The EUT is required to pass operationally. Notes: 1. For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s) and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors. 2. Test 5 simulates a high impedance induction fault. For specific information, please contact Teccor Electronics. 3. Test conditions 6 through 9 are objective, not mandatory, requirements. 4. Sufficient time may be allowed between applications to preclude thermal accumulation. Second Level AC Power Fault Criteria Test conditions for the Second Level AC Power Fault Test are dependent on whether the EUT is intended for customer premises equipment or non-customer premises equipment. In both instances, although the EUT is not required to pass operationally, it may not become a fire, fragmentation, or electrical safety hazard. Second Level AC Power Fault Criteria for Non-customer Premises Equipment Table 4.7 presents test conditions for non-customer premises equipment. (Note that test conditions 1, 3, and 4 may be omitted if the EUT has previously met UL 60950.) See Figure 4.1 for test connection appearances. Table 4.6 First Level AC Power Fault Test Test Applied Voltage, 60 Hz (VRMS) Short Circuit Current per Conductor (A) Duration Primary Protectors Test Connections (Table 4.1, Figure 4.1) 1 (Note 1) 50 0.33 15 min Removed A 2 (Note 1) 100 0.17 15 min Removed A 3 (Note 1) 200, 400, 600 1A at 600 V 60 applications, 1 s each Removed A 4 (Note 4) 1000 1 60 applications, 1 s each In place B 5 (Note 2) N/A N/A 60 applications, 5 s each Removed N/A 6 (Note 3) 600 0.5 30 s Removed A 7 (Note 3) 600 2.2 2 s Removed A 8 (Note 3) 600 3 1 s Removed A 9 (Note 3) 1000 5 0.5 s In place B |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |