20 / 38 page ![]() LP3906 Default Power-Off Sequence 20197811 Symbol Description Min Typ Max Units t 1 Programmable Delay from EN_T deassertion to V CC_Buck1 Off 1.5 ms t 2 Programmable Delay from EN_T deassertion to V CC_Buck2 Off 2 ms t 3 Programmable Delay from EN_T deassertion to V CC_LDO1 Off 3 ms t 4 Programmable Delay from EN_T deassertion to V CC_LDO2 Off 6 ms Note: LP3906 The default Power on delays can be reprogrammed at final test to 0, .5, 1, 2, 5, or 10 ms. Default setting is the same as the on sequence. Power-On-Reset The LP3906 is equipped with an internal Power-On-Reset (“POR”) circuit that will reset the logic when VDD < V POR. This guarantees that the logic is properly initialized when VDD rises above the minimum operating voltage of the Logic and the internal oscillator that clocks the Sequential Logic in the Control section. www.national.com 20 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|