| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
WM9712L bảng dữ liệu(PDF) 44 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM9712L bảng dữ liệu(HTML) 44 Page - Wolfson Microelectronics plc |
|
44 / 77 page ![]() WM9712L Production Data w PD Rev 4.5 August 2006 44 When COO is ‘0’, the WM9712L performs one type of measurement once (in polling mode) or continuously (in continuous mode). The co-ordinate mode (COO = ‘1’) makes it easier to obtain co-ordinate pairs rather than single co- ordinates. In polling-coordinate mode (CTC = ‘0’, COO = ‘1’), the WM9712L performs an X measurement, followed by a Y measurement, followed by an additional measurement determined by ADCSEL, then stops. In continuous-coordinate mode (CTC = ‘1’, COO = ‘1’), the WM9712L continuously repeats a sequence consisting of an X-co-ordinate measurement, followed by a Y co- ordinate measurement, followed by an additional measurement determined by ADCSEL (if ADCSEL = 000, the sequence is XYXYXY… only). DATA READBACK The output data word of the touchpanel interface consists of three parts: • Pen Status (1 bit) – this is also passed to the GPIO logic block, which can be programmed to generate an interrupt and/or wake up the WM9712L on pen down (see GPIO and Interrupt Control). • Output data from the touchpanel ADC (12 bits) • ADCSRC: 3 additional bits that indicate the source of the ADC data. With COO = ‘0’, ADCSRC echoes ADCSEL. However, in co-ordinate mode (COO = ‘1’), the WM9712L schedules different types of measurements autonomously and sets the ADCSRC bits accordingly (see “Measurement Types”). This data is stored in register 7Ah, and can be retrieved by reading the register in the usual manner (see AC-Link Interface section). Additionally, the data can also be passed to the controller on one of the AC-Link time slots not used for audio functions. If the data is being read back using the polling method, there are several ways to determine when a measurement has finished: • Reading back the POLL bit. If it has been reset to ‘0’, then the measurement has finished. • By monitoring the ADA signal, see GPIO and interrupt section • Reading back 7Ah until the new data appears REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION 15 PNDN 0 Pen status (read-only) 0: Pen Up 1: Pen Down 14:12 ADCSRC 000 Touchpanel ADC Source 000: No measurement 001: X co-ordinate measurement 010: Y co-ordinate measurement 011: Pressure measurement (4-wire touchpanels only) 100: COMP1/AUX1 measurement (pin 29) 101: COMP2/AUX2 measurement (pin 30) 110: BMON/AUX3 measurement (pin 31) 111: WIPER/AUX4 measurement (pin 12) 7Ah or AC-Link slot selected by SLT 11:0 ADCD 000h Touchpanel ADC Data (read-only) Bit 11 = MSB Bit 0 = LSB 78h 9 WAIT 0 0: No effect (new ADC data overwrites unread data in register 7Ah) 1: New data is held back, and measurements delayed, until register 7Ah is read) Table 29 Touchpanel Digitiser Data To avoid losing data that has not yet been read, the WM9712L can delay overwriting register 7Ah with new data until the old data has been read. This function is enabled using the WAIT bit. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |